Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: AQUA SEAL MFG & ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AQUA SEAL MFG & ROOFING, INC. in BUILDING 2450 FORT JACKSON, COLUMBIA, SC 29207 (NAICS 238160). OSHA activity number 338977606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aqua Seal MFG & Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Aqua Seal MFG & Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 2450 FORT JACKSON
City
COLUMBIA
State
SC
ZIP
29207
Mailing
PO BOX 2238, WEST COLUMBIA, SC 29171
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
13
Ownership type
A

6 citations on file for this inspection.

1926.20 B01

Deleted Serious Gravity 10 1 instance 13 exposed
Issued
Apr 18, 2013
Abate by
May 14, 2013
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part.   a) Worksite: On or about 03/25/2013 at Fort Jackson, S.C. The employer did not meet the requirements of this standard as evidenced by: No training on fall hazards could be confirmed; No evidence of frequent or regular inspections; No discipline/oversight of employees; No commitment to safety by employer/employee.
Recent events (3)
  • — R (S) $0
  • — C (S) $5390
  • — Z (S) $5390

1926.501 B10

Serious Gravity 10 13 instances 13 exposed
Issued
Apr 18, 2013
Abate by
Apr 24, 2013
Penalty
Initial $5,390 · Current $2,695 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:    a) Roof of Building 2450: Employees engaged in roofing activites were not protected from falling up to 25 feet to the ground below.
Recent events (3)
  • — R (S) $2695
  • — C (S) $5390
  • — Z (S) $5390

1926.502 A02

Serious Gravity 10 1 instance 13 exposed
Issued
Apr 18, 2013
Abate by
Apr 24, 2013
Penalty
Initial $5,390 · Current $2,695 Reduced
29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection.     a) Roof of Building 2450: Employees were required to wear safety harnesses and lanyards while working from roofs ranging in heights from 12 to 25 feet, yet the employer failed to install anchorage points or other means to tie-off those harnesses nor were warning lines or monitors provided.
Recent events (3)
  • — R (S) $2695
  • — C (S) $5390
  • — Z (S) $5390

1926.502 F01 III

Serious Gravity 5 2 instances 13 exposed
Issued
Apr 18, 2013
Abate by
Apr 24, 2013
Penalty
Initial $4,620 · Current $2,310 Reduced
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:     a) Southeast corner of the administration section of  Building 2450: The point of access to the roof was not equipped with two warning lines from the exit point of the extension ladder to the work areas.     b) Northeast corner of the administration section of Building 2450: The point of access to the roof was not equipped with two warning lines from the exit point of the extension ladder to the work areas.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (3)
  • — R (S) $2310
  • — C (S) $4620
  • — Z (S) $4620

1926.503 C03

Deleted Serious Gravity 10 13 instances 13 exposed
Issued
Apr 18, 2013
Abate by
Apr 30, 2013
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill.   a) Roof of Building 2450: Employees working on a roof showed a need for retraining in fall hazards, as evidenced by none of the 13 employees working on the roof and exposed to falls of up to 25 feet felt the need to tie off the lanyards attached to the safety harnesses that they were all wearing.
Recent events (3)
  • — R (S) $0
  • — C (S) $5390
  • — Z (S) $5390

1926.503 B01

Other-than-serious 1 instance 13 exposed
Issued
Apr 18, 2013
Abate by
Apr 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record.   a) Worksite: The employer could not produce a written document stating that had shown that individual employees had received the training required.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (3)
  • — R (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338977606.