OSHA Inspection: GAP VAX, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GAP VAX, INC. in 575 CENTRAL AVENUE, JOHNSTOWN, PA 15902 (NAICS 336211). OSHA activity number 338977853.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GAP VAX, INC. for free Get an email when a new federal OSHA severe-injury report for GAP VAX, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GAP VAX, INC.
Site address
575 CENTRAL AVENUE
City
JOHNSTOWN
State
PA
ZIP
15902
Mailing
575 CENTRAL AVENUE, JOHNSTOWN, PA 15902
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
92
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 2, 2013
Abate by
Sep 3, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 03/27/13, the employer did not conduct periodic inspection of the energy control procedures at least annually to ensure that the procedure and the requirement of this standard were being followed. Employees perform service and maintenance on equipment in the workplace including the Pacific Press, hydraulic 600 ton, Model K600-22, Serial number A1676.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2100

1910.212 A03 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 2, 2013
Abate by
Jul 15, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 04/05/13, an employee was using a foot switch control the Pacific Press, hydraulic 600 ton, Model K600-22, Serial number A1676 without the use of an approved guard or device installed. This arrangement exposed the operator to injury at the point of operation.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2100

1910.332 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 2, 2013
Abate by
Jul 15, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:   (a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 03/27/13, an employee performing troubleshooting of the Sly Air Handler/filter 480 volt, 3 phase electrical system, was not trained in safety-related work practices.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.106 E06 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:  a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 03/27/13, two (2) sixteen gallon containers of multi-use lacquer thinner, and a 55 gallon drum of spent lacquer thinner were not bonded and grounded to prevent the ignition of flammable vapors.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.147 C07 I

Other-than-serious 1 instance 3 exposed
Issued
Jul 2, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 03/27/13, the employer did not ensure that employees performing service and maintenance on equipment including the Pacific Press, hydraulic 600 ton, Model K600-22, Serial number A1676, were provided training in the energy control procedure
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) Workplace, 575 Central Avenue, Johnstown, PA: On or before 03/27/13, an unused opening, approximately 1 inch in diameter, in a Cutler Hammer electrical disconnect box located in the fabrication shop was not effectively closed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338977853.