MASSAPEQUA, NY ·
OSHA Inspection: RUBY'S BAKERY INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RUBY'S BAKERY INC. in 943 N BROADWAY, MASSAPEQUA, NY 11758 (NAICS 311812). OSHA activity number 338979545.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUBY'S BAKERY INC.
- Site address
- 943 N BROADWAY
- City
- MASSAPEQUA
- State
- NY
- ZIP
- 11758
- Mailing
- 150 HICKSVILLE RD, BETHPAGE, NY 11714
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 20
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.22 A01
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. Kitchen, south side - The kitchen floor and passageways were not kept clean in that boxes, cleaning buckets and cooking equipment were disperse all over the floor; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.23 D01 IV
- Issued
- May 31, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iv): Stairway(s) more than 44 inches wide, but less than 88 inches wide having both sides open, did not have one stair railing on each side: Basement stairwell - Stairway, measuring approximately 48.5 inches in width, did not have one handrail on each enclosed side; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.26 C03 VII
- Issued
- May 31, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.26(c)(3)(vii): Portable ladders were used for other uses than that for which they were intended: Kitchen, north/west corner Two sections of extension ladder(s) were laid horizontally and placed on supports to act as shelves. Plywood and other material were stacked onto the ladders for storage; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.36 G02
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Storage area, south side - The storage room adjacent to the kitchen contained items placed in the aisle reducing the access to approximately 16 inches; on or about 03/28/13. b) Kitchen, southeast corner - The access to and from the storage room contained an oven and a refrigerator on either side. The appliances reduced the access to approximately 19.5 inches on; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.37 A03
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Kitchen exit, north - An open flame stove was placed in the exit route; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.37 A01
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.37(a)(1)Exit routes was not kept free of explosive or highly flammable furnishings or other decorations. a) Kitchen exit, north - An open flame stove was placed in the exit route; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 E03
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): The annual maintenace record was not availble to the Assistant Secretary upon request: Kitchen, north exit - Fire extinguisher was positioned on wall and accessible for employee use. The extinguisher did not have an associated maintenance record; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.157 G01
- Issued
- May 31, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: Kitchen, north exit - Fire extinguisher was positioned on wall and accessible for employee use. Employees were not provided with an educational program regarding the use of fire extinguishers; on or about 03/28/13. Abatement Note: By this date the employer must either correct the alleged violation or implement a Fire safety Policy; as outlined in 29 CFR 1910.38(a) and (b), which includes the evacuation requirements of 29 CFR 1910.157(b). Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.263 E01 VIII
- Issued
- May 31, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.263(e)(1)(viii): Horizontal dough mixer(s) were not equipped with a full enclosure over the bowl while the agitator was in motion: a) Kitchen - An I. Kalfus Co., C1403, mixer was used without having an enclosure. Employees were exposed to the rotating agitator; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.303 B02
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Kitchen, center workstation - Electrical outlet boxes were hanging from the ceiling and over a workstation without having been firmly secured; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.304 F01 IV
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a) Kitchen, north wall - Electrical panels were blocked by shelving units, tables and baking supplies. The panels were inaccessible; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.305 B02 I
- Issued
- May 31, 2013
- Abate by
- Jun 6, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Kitchen, north wall - Electrical outlet was secured to wall above a refrigerator. The outlet cover was not secured and did not enclose the installation; on or about 03/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
More inspections in this industry (NAICS 311812)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338979545.