KAHUKU, HI ·
OSHA Inspection: TURTLE BAY RESORTS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TURTLE BAY RESORTS LLC in 57-091 KAMEHAMEHA HIGHWAY, KAHUKU, HI 96731 (NAICS 721110). OSHA activity number 338983166.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TURTLE BAY RESORTS LLC
- Site address
- 57-091 KAMEHAMEHA HIGHWAY
- City
- KAHUKU
- State
- HI
- ZIP
- 96731
- Mailing
- 57-091 KAMEHAMEHA HIGHWAY, KAHUKU, HI 96731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 500
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 B02
- Issued
- Apr 19, 2013
- Abate by
- Apr 29, 2013
- Penalty
- Initial $2,295 · Current $1,721 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) At the facility, in the main kitchen, where the doorway leading to the kitchen on the upper level was not marked "Exit". This condition exposed employees to an inhalation and fire hazard.
Recent events (2)
- · I (S) $1721.25
- · Z (S) $2295
1910.151 C
- Issued
- Apr 19, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $3,060 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) At the facility, in the Housekeeping Chemical Room, where there was no eye wash or other quick drenching station for immediate emergency use. Employees stored and dispensed Fresh & Clean disinfectant cleaner in the Housekeeping Chemical Room.
Recent events (2)
- · I (S) $2295
- · Z (S) $3060
1910.303 B07 I
- Issued
- Apr 19, 2013
- Penalty
- Initial $3,060 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) At the facility, in the Pool Room, where the cover on the Westinghouse MCC G Panel was not effectively closed. This condition exposed employees to an electrical hazard.
Recent events (2)
- · I (S) $2295
- · Z (S) $3060
1910.305 A02 II
- Issued
- Apr 19, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $4,590 · Current $3,443 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ii): Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed: a) At the facility, in the compressor room, where a flexible cord was connected to a junction box that was supplying power to electrical outlets in an office in near the main kitchen area. This condition exposed employees to electrical hazards.
Recent events (2)
- · I (S) $3442.5
- · Z (S) $4590
1910.305 A02 X
- Issued
- Apr 19, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) At the facility, in the compressor room, where a flexible cord was ran beneath two doorways. The flexible cord was supplying power to electrical outlets in an office in near the main kitchen area. This condition exposed employees to electrical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV B
- Issued
- Apr 19, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables may not be used where run through doorways, windows, or similar openings: Compressor room - A flexible cord was ran beneath two doorways. The flexible cord was supplying power to electrical outlets in an office in near the main kitchen area. This condition exposed employees to electrical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.24 F
- Issued
- Apr 19, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: Locksmith room - The stairs leading to the room were not uniform. This condition exposed employees to a trip/fall hazard.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.24 H
- Issued
- Apr 19, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) At the facility, where the stairs leading to the Locksmith room were not equipped with railing. This condition exposed employees to a trip/fall hazard.