Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: 17 MERRILL DRIVE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of 17 MERRILL DRIVE, LLC in 17 MERRILL DRIVE, ROCKLAND, ME 04841 (NAICS 311711). OSHA activity number 338985526.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 17 Merrill Drive, LLC for free Get an email when a new federal OSHA severe-injury report for 17 Merrill Drive, LLC is published. One employer, no account, unsubscribe in one click.
Site address
17 MERRILL DRIVE
City
ROCKLAND
State
ME
ZIP
04841
Mailing
P.O. BOX 368, ROCKLAND, ME 04841
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311711
Employees
53
Ownership type
Private (A)

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 11, 2013
Abate by
Apr 19, 2013
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.23(c)(1):   Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder.  Elevated Storage Area - The platform 9 feet above the floor was not provided with an intermediate rail.
Recent events (2)
  • · I (S) $2625
  • · Z (S) $3500

1910.147 C01

Serious Gravity 10 1 instance 30 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $4,900 · Current $3,675 Reduced
29 CFR 1910.147(c)(1):    Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  Plant Wide - The employer did not establish a lockout/tagout program.
Recent events (2)
  • · I (S) $3675
  • · Z (S) $4900

1910.147 C04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i):   Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   In the following instances machine specific lockout procedures were not developed, documented and utilized:  a) Plant - Steam crab cooker. b) Plant - Leg machine.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 10 7 instances 25 exposed
Issued
Apr 11, 2013
Abate by
May 29, 2013
Penalty
Initial $4,900 · Current $3,675 Reduced
29 CFR 1910.212(a)(1):   One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  In the following instances machines were not guarded:  a)  #1 Leg Machine - The rotating conveyor idler drum and shaft were not guarded.  b)  #2 Leg Machine - The rotating conveyor idler drum and shaft were not guarded. c)  #3 Leg Machine - The rotating conveyor idler drum and shaft were not guarded. d)  Mincer Machine - The rotating cylinders and wing nuts were not guarded. e)  Crab Cooker - The nip points between the conveyor belt and sprocket were not guarded. f)   Crab Slaughter Line - The southern waste conveyor rotating shafts and drums were not guarded. g)  Crab Slaughter Line - The northern waste conveyor rotating shafts and drums were not guarded.
Recent events (2)
  • · I (S) $3675
  • · Z (S) $4900

1910.219 C02 I

Serious Gravity 1 3 instances 15 exposed
Issued
Apr 11, 2013
Abate by
May 29, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.219(c)(2)(i):   All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.  In the following instances shafts were not guarded:  a)  Gill Washer - Drive shaft not guarded. b)  Crab Slaughter Line - Northern cleansing shaft not guarded. c)  Crab Slaughter Line - Southern cleansing shaft not guarded.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $2100

1910.219 C04 I

Serious Gravity 1 2 instances 5 exposed
Issued
Apr 11, 2013
Abate by
May 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i):    Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.  In the following instances shaft ends were not guarded:  a)  #1 Leg Machine - The .75 inch shaft end was not guarded. b)  Mixer - Rotating shaft end not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 A

Serious Gravity 5 4 instances 2 exposed
Issued
Apr 11, 2013
Abate by
Apr 19, 2013
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.333(a):     Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.  Office Area - The 120 volt electrical circuit, supplying power to the four receptacle outlets, was not deenergized and locked out before the outlet covers were removed.
Recent events (2)
  • · I (S) $2625
  • · Z (S) $3500

1910.157 E02

Other-than-serious 1 instance 5 exposed
Issued
Apr 11, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):  Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.  Loading Dock Area - The portable fire extinguisher was not visually inspected monthly.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 1 instance 2 exposed
Issued
Apr 11, 2013
Abate by
Apr 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):    The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.  Maintenance Area - The portable fire extinguisher was last inspected in 2008.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338985526.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.