Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STARTING LINE PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STARTING LINE PRODUCTS, INC. in 743 IONA RD, IDAHO FALLS, ID 83401 (NAICS 332710). OSHA activity number 338985914.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Starting Line Products, INC. for free Get an email when a new federal OSHA severe-injury report for Starting Line Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
743 IONA RD
City
IDAHO FALLS
State
ID
ZIP
83401
Mailing
743 IONA RD, IDAHO FALLS, ID 83401
Inspection type
Planned (H)
Scope
Records only (C)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
56
Ownership type
Private (A)

3 citations on file for this inspection.

1910.37 B02

Other-than-serious 2 instances 10 exposed
Issued
May 30, 2013
Abate by
Jun 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) Weld shop: On or about March 28, 2013 and at times prior thereto, two exit doors had signs removed identifiying those doors as exits.  Note: Abatement certification is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E02

Other-than-serious 1 instance 4 exposed
Issued
May 30, 2013
Abate by
Jun 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) R&D shop: On or about March 28, 2013 and at times prior thereto, portable fire extinguishers had not been receiving monthly checks to ensure proper charge and working order.  Note: Abatement certification is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B02

Other-than-serious 4 instances 10 exposed
Issued
May 30, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Weld shop: On or about March 28, 2013 and at times prior thereto, several electical junction boxes were used in a pendant style and had not been mounted as they were designed to be.     Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0