DEFIANCE, OH ·
OSHA Inspection: DEFIANCE METAL PRODUCTS CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DEFIANCE METAL PRODUCTS CO. in 21 SENECA ST., DEFIANCE, OH 43512 (NAICS 332116). OSHA activity number 338986318.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEFIANCE METAL PRODUCTS CO.
- Site address
- 21 SENECA ST.
- City
- DEFIANCE
- State
- OH
- ZIP
- 43512
- Mailing
- 21 SENECA ST., DEFIANCE, OH 43512
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 110
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 8, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $5,500 · Current $3,950 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure written energy control procedures were implemented to control all hazardous energy sources of the Danly 1000 Press #3077. An employee was exposed to the gravitational energy of the ram and residual energy of the flywheel when changing the die stamp located within the die.
Recent events (2)
- · I (S) $3950
- · Z (S) $5500
1910.147 D05 I
- Issued
- Jul 8, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, employees were exposed to potentially hazardous stored energy when accessing the hazard area of the Danly 1000 Press #3077 to perform a stamp change. The gravitational energy of the ram and the residual energy of the flywheel was not controlled before employees set up the press.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.217 E03
- Issued
- Jul 8, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(e)(3): Original and continuing competence of personnel maintaining mechanical power press(es) was not insured: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer did not assure that employees who serviced mechanical power presses were trained to maintain press safeguards. The original and continuing competence of personnel servicing power presses was not maintained in that employees operated presses that were not guarded properly and/or employees set up die stamps without controlling all hazardous energy sources.
Recent events (2)
- · I (S) $0
- · Z (S) $7000
1910.217 C03 I E
- Issued
- Jul 8, 2013
- Abate by
- Jul 18, 2013
- Penalty
- Initial $7,000 · Current $4,850 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(i)(e): The location of the hand controls did not allow a safe distance from the point of operation so that the slide completes the downward travel or stops before the operator can reach into the point of operation with his hands: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure that the two hand controls on the Bliss press #1003 were located at a safe distance from the point of operation to protect the operator from amputation injuries. b) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure that the two hand controls on the Minster press #1078 (s/n 50-8-4236) were located at a safe distance from the point of operation to protect the operator from amputation injuries. c) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure that the two hand controls on the Minster press #1009 (s/n 50-7 1/2-3801) were located at a safe distance from the point of operation to protect the operator from amputation injuries.
Recent events (2)
- · I (S) $4850
- · Z (S) $7000
1910.217 C03 VII D
- Issued
- Jul 8, 2013
- Abate by
- Jul 18, 2013
- Penalty
- Initial $7,000 · Current $4,850 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(vii)(d): Two hand controls used with mechanical power press(es) were not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure the two hand controls for the Verson Press #3103 (s/n 11119) were located in a fixed position so that only a supervisor or safety engineer could relocate the controls. Employees operating the press were exposed to amputation hazards in that the two hand controls could easily be relocated closer to the point of operation. b) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure the two hand controls used to operate the Verson Press #1103 (s/n 10926) were located in a fixed position so that only a supervisor or safety engineer could relocate the controls. Employees operating the press were exposed to amputation hazards in that the two hand controls were able to be easily relocated closer to the point of operation. c) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure that the two hand control pedestal used to operate the Minster Press #1078 (s/n 50-8-4236) was in a fixed position. Employees operating the press were exposed to amputation hazards in that the pedestal was not secured and could be moved and operated directly adjacent to the hazard area. d) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer failed to assure that the two hand control pedestal, used to operate the Minster Press #1009 (s/n 50-7 1/2-3801), was in a fixed position. Employees operating the press were exposed to amputation hazards in that the pedestal was not secured and could be moved and operated directly adjacent to the hazard area.
Recent events (2)
- · I (S) $4850
- · Z (S) $7000
1910.217 F02
- Issued
- Jul 8, 2013
- Abate by
- Jul 25, 2013
- Penalty
- Initial $5,500 · Current $3,950 Reduced
General-duty citation text
29 CFR 1910.217(f)(2): Supervision to ensure that correct operating procedures were being followed on mechanical power press(es) was inadequate: a) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer did not assure that the operator of the Bliss 200 mechanical power press #1003 was instructed in the safe operation of the press in that the selector switch for the press run mode was not supervised. The key, used to change press modes, was kept in the selector switch and not supervised to assure that the press mode was not changed without the operator's knowledge. b) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer did not assure that the operator of the Minster 290 mechanical power press #1078 was instructed in the safe operation of the press in that the selector switch for the press run mode was not supervised. The key, used to change press modes, was kept in the selector switch and not supervised to assure that the press mode was not changed without the operator's knowledge. c) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer did not assure that the operator(s) of the Danly 1000 mechanical power press #3077 was instructed in the safe operation of the press in that the selector switch for the press run mode was not supervised. The key, used to change press modes, was kept in the selector switch and not supervised to assure that the press mode was not changed without the operator's knowledge. d) Defiance Metal Products Co. - Defiance, Ohio: On or about April 2, 2013, the employer did not assure that the operator of the Verson 350 mechanical power press #3103 was instructed in the safe operation of the press in that the selector switch for the press run mode was not supervised. The key, used to change press modes, was kept in the selector switch and not supervised to assure that the press mode was not changed without the operator's knowledge.
Recent events (2)
- · I (S) $3950
- · Z (S) $5500
More inspections at Defiance Metal Products CO.