Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: RAUL GRANADOS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAUL GRANADOS in 707 CIELO AZUL, ALAMOSA, CO 81101 (NAICS 238390). OSHA activity number 338987431.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Raul Granados for free Get an email when a new federal OSHA severe-injury report for Raul Granados is published. One employer, no account, unsubscribe in one click.
Establishment
RAUL GRANADOS
Site address
707 CIELO AZUL
City
ALAMOSA
State
CO
ZIP
81101
Mailing
108 W. 7TH AVE, ANTONITO, CO 81120
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
2
Ownership type
Private (A)

7 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $2,000 · Current $250 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    (a)  On or about March 28, 2013, employees were exposed to fall hazards from a scaffold that was approximately 15 feet high and was not fully planked.    Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $250
  • · Z (S) $2000

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end:  (a)  On or about March 28, 2013, employees were exposed to fall hazards from a scaffold whose planking extended more than 18 inches past the load bearing supports.   Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $2,000 · Current $250 Reduced
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units:    (a)  On or about March 28, 2013, employees were exposed to fall hazards from a scaffold platform that was supported by a closed step ladder.      Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $250
  • · Z (S) $2000

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  (a)  On or about March 28, 2013, employees were exposed to fall hazards from a scaffold that was improperly supported and inadequately planked.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $2,000 · Current $250 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    (a)  On or about March 28, 2013, employees were exposed to fall hazards when climbing the supporting closed stepladder and planking to get onto the pump jack scaffold platform.      Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $250
  • · Z (S) $2000

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $2,000 · Current $250 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a)  On or about March 28, 2013, employees were exposed to fall hazards from a scaffold that was approximately 15 feet high that had no guardrails, personal fall arrest systems, or any other fall protection system.    Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $250
  • · Z (S) $2000

1926.1052 C01 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 29, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a)  On or about March 28, 2013, the employer did not protect employees from falls on the stairway from the first to the second floor of the building in that it did not have a handrail.    Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0