OSHA Inspection: WASTE SERVICES OF FLORIDA INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WASTE SERVICES OF FLORIDA INC. in 13300 NW 38TH CT, OPA LOCKA, FL 33054 (NAICS 562111). OSHA activity number 338988942.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Waste Services of Florida INC. — free Get an email when a new federal OSHA severe-injury report for Waste Services of Florida INC. is published. One employer, no account, unsubscribe in one click.
Site address
13300 NW 38TH CT
City
OPA LOCKA
State
FL
ZIP
33054
Mailing
3840 NW 37TH CT, MIAMI, FL 33142
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
45
Ownership type
A

5 citations on file for this inspection.

1910.23 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  a.  On or about April 3, 2013,  at the above addressed jobsite, an employee was exposed to a fall hazard while working in close proximity to an open sided floor that had a chain railing which lacked an intermediate rail and a toprail was placed at 26.5 inches from floor level.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2013
Penalty
Initial $2,385 · Current $1,431 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least half-hour:   a.  On or about April 3, 2013,  at above addressed jobsite, employees were exposed to a fire hazard while working in an area where an oxygen and an acetylene cylinder were stored together with installed regulators.
Recent events (2)
  • — I (S) $1431
  • — Z (S) $2385

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a.  On or about April 3, 2013,  at above addressed jobsite,, an employee was exposed to an electrical hazard while using an extension cord that lacked a ground prong on its attachment plug.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1904.32 B06

Other-than-serious 1 instance 1 exposed
Issued
Apr 30, 2013
Penalty
Initial $935 · Current $561 Reduced
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1st and April 30th:   a.  On or about April 3, 2013,  at above addressed jobsite, the OSHA Form 300A for 2012 was not posted.
Recent events (2)
  • — I (O) $561
  • — Z (O) $935

1910.1200 G08

Other-than-serious 1 instance 2 exposed
Issued
Apr 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  a.  On or about 4/3/2013, April 3, 2013,  at above addressed jobsite, employees were exposed to a chemical hazard while performing preventive vehicle maintenance as material safety data sheets were not maintained for: Mobil Nuto H68, Mobil Delvac 15W-40, 50/50 Extended life metal guard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Waste Services of Florida INC.'s full OSHA safety record →