ATHENS, GA ·
OSHA Inspection: RIMFIRE ELECTRIC LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIMFIRE ELECTRIC LLC in 1791 OCONEE CONNECTOR, ATHENS, GA 30606 (NAICS 238210). OSHA activity number 338989452.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIMFIRE ELECTRIC LLC
- Site address
- 1791 OCONEE CONNECTOR
- City
- ATHENS
- State
- GA
- ZIP
- 30606
- Mailing
- 611 GRASSDALE RD STE A, CARTERSVILLE, GA 30121
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B01
- Issued
- Apr 5, 2013
- Penalty
- Initial $2,380 · Current $2,975
General-duty citation text
29 CFR 1926.403(b)(1): The employer did not ensure that electrical equipment was free from recognized hazards that are likely to cause death or serious physical harm to employees. On or about 4/1/13, the employer did not ensure the 240/480 volt electrical equipment mounted on the wooden board was stable in that the board was left unsecured against the back wall and was not stabilized in a way to prevent the equipment from being knocked or turning over. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $2975
- · Z (S) $2380
1926.405 E01
- Issued
- Apr 5, 2013
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures. On 4/1/13, at the Athens job site, employees were exposed to electrical hazards as a 240/480 volt electrical panel was not protected from rain water and water splash hazards as it was located in an area of an unfinished building at the job site. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $2975
1926.503 A01
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. On 4/1/13, the employer did not provide a training program for emploeyes exposed to fall hazards and who have been provided fall protection and required to use the protection by the company. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $2380
More inspections in this industry (NAICS 238210)