OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS MATES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS MATES in BLDG 21066 HWY 101, CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 811111). OSHA activity number 338990898.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CA Army National Guard - Camp Roberts Mates — free Get an email when a new federal OSHA severe-injury report for CA Army National Guard - Camp Roberts Mates is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 21066 HWY 101, CAMP ROBERTS
City
SAN MIGUEL
State
CA
ZIP
93451
Mailing
PO BOX 397, SAN MIGUEL, CA 93451
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
75
Ownership type
D

6 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 5 instances 15 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  (a) Team three bay: On or about 27MAR13, a single throw knife switch was locked out without being included in the hazardous energy control program.  (b) Armament: On or about 27MAR13, a single throw knife switch was locked out without being included in the hazardous energy control program.   (c) Team one bay: On or about 27MAR13, a single throw knife switch was locked out without being included in the hazardous energy control program.  (d) Team one bay: On or about 27MAR13, a single throw knife switch was locked out without being included in the hazardous energy control program.   (e) Team two bay: On or about 27MAR13, a single throw knife switch was locked out without being included in the hazardous energy control program.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 5 1 instance 15 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:   Armament: On or about 27MAR13, employees operating powered industrial vehicles were permitted to operate vehicles without their performance being evaluated by the employer for over three years.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 2 instances 5 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) Team four bay: On or about 27MAR13, access to a single throw knife switch was obstructed by equipment.  (b) Team two bay: On or about 27MAR13, access to a single throw knife switch was obstructed by a large cabinet.
Recent events (1)
  • — Z (S) $0

1910.304 F01 VIII

Serious Gravity 5 4 instances 15 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits shall be listed and marked "SWD."  (a) Team four bay, On or about 27MAR13, the lights in the main bay are controlled by breakers in a circuit panel, the breakers are not marked SWD for switch duty for use as light switches.  (b) Team three bay, On or about 27MAR13, the lights in the main bay are controlled by breakers in a circuit panel, the breakers are not marked SWD for switch duty for use as light switches.  (c) Team two bay, On or about 27MAR13, the lights in the main bay are controlled by breakers in a circuit panel, the breakers are not marked SWD for switch duty for use as light switches.  (d) Team one bay, On or about 27MAR13, the lights in the main bay are controlled by breakers in a circuit panel, the breakers are not marked SWD for switch duty for use as light switches.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 3 instances 15 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii) Unused openings in boxes, cabinets, or fittings were not effectively closed:   (a) Team three bay, On or about 27MAR13, openings in the side of a circuit breaker panel plugs were left open exposing employees to inadvertent contact with live conductors.  (b) Team one bay, On or about 27MAR13, openings in the side of a circuit breaker panel plugs were left open exposing employees to inadvertent contact with live conductors.  (c) Team two bay, On or about 27MAR13, conductors were exposed where a light bulb was replaced on a bench grinder.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 3 instances 15 exposed
Issued
Apr 23, 2013
Abate by
May 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and cables were not used as permitted by 29 CFR 1910.305(g)(1)(iv)(A) through (F):   (a) Team four bay: On or about 27MAR13, a flexible cord was attached to a work desk.    (b) Team three office: On or about 27MAR13, a flexible cord was used as a substitute for the fixed wiring of the building.    (c) Team two bay: On or about 27MAR13, a flexible cord was attached to the building surface.
Recent events (1)
  • — Z (S) $0

View CA Army National Guard - Camp Roberts Mates's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338990898.