Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SCHAEFER GRAIN & FEED INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHAEFER GRAIN & FEED INC. in 210 SOUTH 9TH, PLAINVIEW, NE 68769 (NAICS 424510). OSHA activity number 338991458.

Watch Schaefer Grain & Feed INC. — free Get an email when a new federal OSHA severe-injury report for Schaefer Grain & Feed INC. is published. One employer, no account, unsubscribe in one click.
Site address
210 SOUTH 9TH
City
PLAINVIEW
State
NE
ZIP
68769
Mailing
P O BOX 267, PLAINVIEW, NE 68769
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1301.00 · Current $1301.00
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  Job site located at 210 S 9th, Plainview, NE 68769-The employer did not ensure that oxygen cylinders in storage were separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire resistance rating of at least one-half hour.
Recent events (1)
  • — Z (S) $1301

1910.303 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1224.00 · Current $1224.00
29 CFR 1910.303(f): Disconnecting means and circuits --  Job site located at 210 S 9th, Plainview, NE 68769-The employer had an electrical panel in the storage building that did not have the breakers legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
Recent events (1)
  • — Z (S) $1224

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338991458.