Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANCOR INDUSTRIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MANCOR INDUSTRIES, INC. in 600 KISER STREET 1008 LEONHARD STREET, DAYTON, OH 45404 (NAICS 332116). OSHA activity number 338992746.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mancor Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Mancor Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 KISER STREET 1008 LEONHARD STREET
City
DAYTON
State
OH
ZIP
45404
Mailing
1008 LEONHARD STREET, DAYTON, OH 45404
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
230
Ownership type
A

3 citations on file for this inspection.

1910.101 B

Serious Gravity 5 2 instances 230 exposed
Issued
Jul 2, 2013
Penalty
Initial $5,049 · Current $3,534 Reduced

Hazardous substances X100

29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    (a)  Compressed gas cylinders, which were full of oxygen, were not properly supported to prevent them from being knocked over as required by Compressed Gas Association Pamphlet P-1-1965, Section 3.4.4.     (b)  Compressed gas cylinders, which were empty of oxygen, were not properly supported to prevent them from being knocked over as required by Compressed Gas Association Pamphlet P-1-1965, Section 3.4.4.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3534.3
  • — Z (S) $5049

1910.147 C06 I

Repeat 1 instance 230 exposed
Issued
Jul 2, 2013
Abate by
Jul 29, 2013
Penalty
Initial $198 · Current $198
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a)  The employer had not performed periodic inspections of employees who performed lock out/tag out of hazardous energy as part of their job duties in over 3 years.    Mancor Industries, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(ii), which was contained in OSHA inspection number OIS 86557 (IMIS 312738065), citation number 2, item number 1, and was affirmed as a final order on January 25, 2010, with respect to workplaces located at 1008 Leonhard Street and 600 Kiser Street, Dayton, OH.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • — I (R) $198
  • — Z (R) $198

1910.1200 F06 II

Repeat 1 instance 230 exposed
Issued
Jul 2, 2013
Abate by
Jul 29, 2013
Penalty
Initial $198 · Current $198
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:    (a)  A spray bottle on a table in the laser area was not labeled with the contents of the container or the hazards of the chemicals it contained.       Mancor Industries, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(f)(5)(i), which was contained in OSHA inspection number OIS 85992 (IMIS 12738099), citation number 2, item number 2, and was affirmed as a final order on January 25, 2010, with respect to workplaces located at 1008 Leonhard Street and 600 Kiser Street, Dayton, OH.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • — I (R) $198
  • — Z (R) $198

View Mancor Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338992746.