Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: GREENWAY MEWS REALTY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GREENWAY MEWS REALTY in 17 LITTLE WEST 12TH ST., NEW YORK, NY 10014 (NAICS 531120). OSHA activity number 338993371.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Greenway Mews Realty for free Get an email when a new federal OSHA severe-injury report for Greenway Mews Realty is published. One employer, no account, unsubscribe in one click.
Site address
17 LITTLE WEST 12TH ST.
City
NEW YORK
State
NY
ZIP
10014
Mailing
416 W 13TH ST., NEW YORK, NY 10014
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531120
Employees
12
Ownership type
A

7 citations on file for this inspection.

1926.403 E

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Jul 30, 2013
Penalty
Initial $2,000 · Current $1,300 Reduced
29 CFR 1926.403(e): Conductors were not spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.        a) Stairwell B:        Employees used temporary lighting and outlet devices installed on a wood pole scaffold for working with electric powered hand tools. The lighting fixtures and outlet devices were wired to a circuit breaker through temporary electrical conductors, which were not spliced or joined with splicing devices designed for the use. All splices and joints were not covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose. On or about 04/05/13.        NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1300
  • · Z (S) $2000

1926.416 E02

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Jul 30, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.416(e)(2): Extension cords were fastened with staples, hung from nails, or suspended by wire:       a) Stairwell B:       Employees used temporary lighting and outlet devices installed on a wood pole scaffold for working with electric powered hand tools. The lighting fixtures and outlet devices were wired to a circuit breaker through temporary wirings, which were fastened to the scaffold with staples. On or about 04/05/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Jul 30, 2013
Penalty
Initial $2,000 · Current $1,300 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.       a) Stairwell B:       Employees used electric powered hand tools to remove plaster and stucco on the stairwell walls. The hand tools were connected to extension cords, which were routed to temporary outlet devices installed on a wood pole scaffold. The hand tools and extension cords were not provided with ground fault circuit interrupters. On or about 04/05/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1300
  • · Z (S) $2000

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2013
Abate by
Aug 6, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.       a) Stairwell B:       Two employees constructed a wood pole scaffold on the staircase around the stairwell from basement level to roof bulkhead and worked from this scaffold. The scaffold was not erected by experienced and trained employees under the supervision and direction of a competent person. Employees who erected and worked on the scaffolds were exposed to hazards, including but not limited to: Diagonal bracing were not installed across vertical pole supports, and wooden scaffold poles were improperly spliced. On or about 04/05/13.       NOTE:  IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 18, 2013
Abate by
Aug 6, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.       a) Stairwell B:       The employer did not provide training to employees who erected and worked from a wood pole scaffold built on the staircase around the stairwell from basement level to roof bulkhead. Employees could not recognize hazards associated with pole scaffolds, and were exposed to hazards, including but not limited to: Diagonal bracing were not installed across vertical pole supports, and wooden scaffold poles were improperly spliced. On or about 04/05/13.       NOTE:  IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1926.452 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2013
Abate by
Jul 30, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds.       a) Stairwell B:       Two employees constructed a wood pole scaffold on the staircase around the stairwell from basement level to roof bulkhead and worked from this scaffold. Diagonal bracing in both directions were not installed across the vertical pole supports of the scaffold. On or about 04/05/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.452 A09

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2013
Abate by
Jul 30, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.452(a)(9): Where wooden poles are spliced, the ends shall be squared and the upper section shall rest squarely on the lower section. Wood splice plates shall be provided on at least two adjacent sides, and shall extend at least 2 feet (0.6 m) on either side of the splice, overlap the abutted ends equally, and have at least the same cross-sectional areas as the pole. Splice plates of other materials of equivalent strength may be used.      a) Stairwell B:       Two employees constructed a wood pole scaffold on the staircase around the stairwell from basement level to roof bulkhead and worked from this scaffold. Where wooden poles are spliced on this scaffold, the upper sections were not rested on the lower sections, and wood splice plates were not provided on either side of the splices. On or about 04/05/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

View Greenway Mews Realty's full OSHA safety record →