On , OSHA opened a planned safety inspection of ALLEN-MITCHELL & CO. in 515 V STREET, NE, WASHINGTON, DC 20002 (NAICS 332710). OSHA activity number 338993868.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allen-Mitchell & CO. — free Get an email when a new federal OSHA severe-injury report for Allen-Mitchell & CO. is published. One employer, no account, unsubscribe in one click.
Site address
515 V STREET, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
515 V STREET, NE, WASHINGTON, DC 20002
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
14
Ownership type
A

12 citations on file for this inspection.

1910.36 D01

Other-than-serious 1 instance 3 exposed
Issued
Apr 19, 2013
Abate by
Apr 25, 2013
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    a) Exterior Rear of Building - Outside emergency exit fenced gate was chained and bolted blocking access to public space in the event of an emergency, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $2000

1910.106 E09 III

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Apr 19, 2013
Abate by
Apr 25, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  a) Rear of Main Shop - Oily paper towels were dumped into metal drums without metal lids causing a fire hazard, on or about 04/04/13  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.106 E02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 19, 2013
Abate by
Apr 25, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers:    a) Truck Maintenance Garage -  A 225 gallon metal container was used to store used motor oil and missing both of the bung caps, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1910.151 C

Other-than-serious 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
May 9, 2013
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Battery Charging Area - Employees were connecting batteries for recharging of the Clark electric powered industrial truck and an eye wash station was not provided, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $2000

1910.212 A01

Deleted Serious Gravity 5 7 instances 4 exposed
Issued
Apr 19, 2013
Abate by
May 24, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Main Shop Area - Employees were not protected from accidental  contact with the lathes' rotating chucks and bits on or about 4/04/13 on the following equipment:                          1.  Standard Modern Metal Lathe, Model #17/60, Serial # 6227 with a 12 inch rotating chuck and bit.                 2.  Standard Modern Metal Lathe, with a 30 inch rotating chuck and bit.                   3.  Pratt & Whitney Metal Lathe, Serial # GEJ-881A.                 4.  LeBlond Regal Metal Lathe, Serial # AH763.                  5.  LeBlond Regal Metal Lathe, Serial # BX825.                 6.  Standard Modern 26/120 Metal Lathe, Serial  #20121.                    7.  Standard Modern 20/120 Metal Lathe, Serial # 8409.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.242 B

Other-than-serious 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
May 24, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) Main Shop Area - An employee was observed using a hand held air nozzle with the pressure set at 100 psi, while cleaning metal shavings and dust from work, while using a metal lathe, on or about 04/04/14.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $1600

1910.253 B02 II

Other-than-serious 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
Apr 29, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.253(b)(2)(ii): Compressed gas cylinders were not located in assigned storage spaces that were located where cylinders would not be knocked over or damaged by passing or falling objects:     a) Battery Charging Area - Oxygen, acetylene, and argon compressed gas cylinders were stored next to a battery charging area where the cylinders could be struck by a Clark powered industrial truck, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $1600

1910.253 B02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
Apr 19, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    a) Rear of Main Shop - Two acetylene gas cylinders were being stored and not provided with a valve cap, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1910.253 B04 III

Other-than-serious 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
Apr 25, 2013
Penalty
Initial $1,600 · Current $1,100 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one hour:    a) Rear of Main Shop Area - Four oxygen and two acetylene cylinders were stored together and not seperated by at least 20 feet, on or about 04/04/13    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $1600

1910.305 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 19, 2013
Abate by
May 4, 2013
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1910.305(d)(2): Panelboards mounted in cabinets, cutout boxes, or enclosures designed for the purpose and was not dead front:    a) Electric Room - An electrical service panel was missing the cover exposing employees to live electrical parts, 100 amp service, on or about 04/04/13.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1910.37 A04

Other-than-serious 1 instance 6 exposed
Issued
Apr 19, 2013
Abate by
Apr 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  a) Rear of Building -  Emergency exit sign was burned out, on or about 04/04/13.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 6 exposed
Issued
Apr 19, 2013
Abate by
May 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Electric Room - The space in front of service panels were cluttered with storage including but not limited to; cardboard boxes, cutting torch and hoses, hand tools and portable electric tools, and floor mats, on or about 04/04/13.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date completed, method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0