Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS SOLIS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LUIS SOLIS in 8901 ANTERES PARK DRIVE, COLUMBUS, OH 43240 (NAICS 238130). OSHA activity number 338994072.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Solis — free Get an email when a new federal OSHA severe-injury report for Luis Solis is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS SOLIS
Site address
8901 ANTERES PARK DRIVE
City
COLUMBUS
State
OH
ZIP
43240
Mailing
2300 MORNING VIEW, HILLIARD, OH 43026
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.405 A02 II J

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 24, 2013
Abate by
May 14, 2013
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage. NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO).  a. On the third floor of the building where employees were cutting fire block material, the extension cord being used was not rated for hard or extra-hard usage and the outer insulation was coming apart in several areas, thereby exposing employees to a contact hazard.
Recent events (1)
  • — Z (S) $1020

1926.405 G02 IV

Serious Gravity 1 2 instances 6 exposed
Issued
Apr 24, 2013
Abate by
May 14, 2013
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. At the west side of the building where the extension cord was plugged into the temporary receptacle, the strain relief was pulled away from the outer insulation of the yellow cord, thereby exposing employees to a contact hazard.  b. On the third floor where employees were cutting fireblock material, the strain relief was pulled away from the outer insulation of the oarnge cord, thereby exposing employees to a contact hazard.
Recent events (1)
  • — Z (S) $1020

1926.1053 B01

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 24, 2013
Abate by
May 14, 2013
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. On the North side of building 860-870 where employees accessed the second level, the ladder did not extend at least 3 feet above the upper landing surface, thereby exposing employees to a fall hazard.
Recent events (1)
  • — Z (S) $1020

1926.1053 B05 I

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 24, 2013
Abate by
May 14, 2013
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).   a. On the North side of building 860-870 where employees accessed the second level, the feet of the ladder were placed six feet from the wall while the ladder was 10 feet, 7 inches from the ground to the landing, thereby exposing employees to a fall hazard.
Recent events (1)
  • — Z (S) $1020

View Luis Solis's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338994072.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.