EAST BOSTON, MA —
OSHA Inspection: BOSTON BOATWORKS, L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOSTON BOATWORKS, L.L.C. in 256 MARGINAL STREET, EAST BOSTON, MA 02128 (NAICS 336612). OSHA activity number 338994312.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOSTON BOATWORKS, L.L.C.
- Site address
- 256 MARGINAL STREET
- City
- EAST BOSTON
- State
- MA
- ZIP
- 02128
- Mailing
- 256 MARGINAL STREET, EAST BOSTON, MA 02128
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 44
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 B01 II
- Issued
- Sep 30, 2013
- Abate by
- Nov 20, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Upper Shop: A double duplex receptacle box that energized portable equipment was not effectively closed.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- Sep 30, 2013
- Abate by
- Nov 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Woodworking Shop: The following extension cords were used in lieu of fixed wiring to energize various electrical equipment: a) An extension cord that was glued to a vertical support beam was used to energize equipment such as a router table. b) An extension cord that was wrapped around various structures on the ceiling and wall was used to energize a suspended ceiling light fixture.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Boston Boatworks, L.L.C.
View Boston Boatworks, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338994312.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.