BIRMINGHAM, AL ·
OSHA Inspection: COIL MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COIL MANUFACTURING, INC. in 940 ALTON PARKWAY, BIRMINGHAM, AL 35210 (NAICS 335312). OSHA activity number 338995814.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COIL MANUFACTURING, INC.
- Site address
- 940 ALTON PARKWAY
- City
- BIRMINGHAM
- State
- AL
- ZIP
- 35210
- Mailing
- 940 ALTON PARKWAY, BIRMINGHAM, AL 35210
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 67
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.212 B
- Issued
- May 28, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or about 04/05/13, 940 Alton Parkway, Birmingham, AL 35210, maintenance shop, the Porter & Cable drill press was not bolted to the floor to prevent accidental movement or knock-over when in use.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.215 A04
- Issued
- May 28, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about 04/05/13, 940 Alton Parkway, Birmingham, AL 35210, maintenance shop, the work rest on the 8-inch bench grinder was not adjusted to within one eighth inch of the abrasive wheel.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.219 D01
- Issued
- May 28, 2013
- Abate by
- Jun 14, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about 04/05/13, 940 Alton Parkway, Birmingham, AL 35210, taping department, the pulleys on the taping machines were not guarded.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.219 E01 I
- Issued
- May 28, 2013
- Abate by
- Jun 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) On or about 04/05/13, 940 Alton Parkway, Birmingham, AL 35210, taping department, taping machine, the three-eighth inch rubberized belts on the taping machines were not guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- May 28, 2013
- Abate by
- May 28, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about 04/05/13, receiving department, the 110 volt electrical outlet box powering the floor fan was not mounted to a surface.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.132 D02
- Issued
- May 28, 2013
- Abate by
- Jun 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) On or about 04/05/13, 940 Alton Parkway, Birmingham, AL 35210, the employer did not certify that the required hazard assessment of the workplace had been performed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 335312)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338995814.