Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: NANO TEKON

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NANO TEKON in 650 IWILEI RD., HONOLULU, HI 96817 (NAICS 561790). OSHA activity number 338995962.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nano Tekon for free Get an email when a new federal OSHA severe-injury report for Nano Tekon is published. One employer, no account, unsubscribe in one click.
Establishment
NANO TEKON
Site address
650 IWILEI RD.
City
HONOLULU
State
HI
ZIP
96817
Mailing
906 KOKO ISLE CIR, HONOLULU, HI 96825
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1910.67 C02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 23, 2013
Abate by
Apr 23, 2013
Penalty
Initial $2,400 · Current $1,500 Reduced
29 CFR 1910.67(c)(2)(iv):  The employer did not ensure employees stood firmly on the floor of the basket and did not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position:     a)  At the site, where the employees stood and sat on the JLG aerial lift, model #450AJ SII, serial #0300073873, guard railing to sand and clean exterior building windows.  This condition exposed the employees to a fall hazard.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2400

1910.67 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 23, 2013
Abate by
Apr 23, 2013
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1910.67(c)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift:    a)  At the site, where an employee was working from a JLG aerial lift, model #450AJ SII, serial #0300073873, without wearing a body belt and lanyard.  The employee had a rope tied around his waist while he was performing window washing activities from the aerial lift guard railing system.  This condition exposed the employees to a fall hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2400

1910.304 B03 II C 3

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 23, 2013
Abate by
Apr 23, 2013
Penalty
Initial $2,400 · Current $1,500 Reduced
29 CFR 1910.304(b)(3)(ii)(C)(3):  Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired:    a)  At the site, where the outer sheathing of a blue flexible cord was damaged and not removed from service.  The flexible cord was supplying power to a hand held Makita sander.  This condition exposed the employees to an electrical hazard.    b)  At the site, where the ground pin was missing from the orange flexible cord and was not removed from service.  The flexible cord was supplying power to a hand held sander.  This condition exposed the employees to an electrical hazard.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2400

1910.334 A02 II

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made:  a)  At the site, where the outer sheathing of a blue flexible cord was damaged and not removed from service.  The flexible cord was supplying power to a hand held Makita sander.  This condition exposed the employees to an electrical hazard.  b)  At the site, where the ground pin was missing from the orange flexible cord and was not removed from service.  The flexible cord was supplying power to a hand held sander.  This condition exposed the employees to an electrical hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338995962.