WEST HAVEN, CT —
OSHA Inspection: DEGRAND & SONS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEGRAND & SONS INC in 430 ISLAND LANE, WEST HAVEN, CT 06516 (NAICS 484220). OSHA activity number 338996135.
Where did this inspection happen?
- Establishment
- DEGRAND & SONS INC
- Site address
- 430 ISLAND LANE
- City
- WEST HAVEN
- State
- CT
- ZIP
- 06516
- Mailing
- PO BOX 16609, WEST HAVEN, CT 06516
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484220
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1470.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: Facility: The employer did not verify though a written certification that the Workplace Hazard Assessment for personal protective equipment (PPE) was appropriately conducted.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer. Facility: The employees who were voluntary wearing N95 respirators were neither given a copy of Appendix D information nor an explanation of its contents.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1470.00 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: Establishment: The following powered industrial truck (PIT) had the following defective parts and was not removed from service. 1. The Raymond pallet jack serial number 112TM FRE 60L the emergency stop was not working.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.304 F01 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were located in the vicinity of easily ignitable material and not readily accessible to each employee or authorized building management personnel. Warehouse: The electrical panels/boxes for the circuit breakers having built-in over current protection devices were blocked by large battery charger that was used to charge the batteries for powered industrial trucks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 484220)
ELMA, WA—2026-07-01
WA317991900 - TWO FEATHERS TRUCKING LLC
SAN ANTONIO, TX—2026-07-01
ADT TRUCKING LP
EDGEWOOD, TX—2026-06-26
BASS SERVICES, INC.
VALLEY FALLS, NY—2026-06-24
EARL T. WADHAMS, INC.
ARLINGTON, OR—2026-06-23
317744605 - WALSH TRUCKING CO LTD
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338996135.