Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: STEVENSON CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEVENSON CONSTRUCTION INC. in 611 SCENIC RIDGE DRIVE, VENETIA, PA 15367 (NAICS 238140). OSHA activity number 338996226.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stevenson Construction INC. for free Get an email when a new federal OSHA severe-injury report for Stevenson Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
611 SCENIC RIDGE DRIVE
City
VENETIA
State
PA
ZIP
15367
Mailing
5111 DOLORES DRIVE, PITTSBURGH, PA 15227
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 16, 2013
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:        (a) Jobsite:  On or about April 5, 2013, employees were using the tubular welded frame scaffolding uprights to access/egress the scaffolding.  The fall hazard to the employees was up to approximately 14 feet to the ground.
Recent events (3)
  • · F (S) $1224
  • · C (S) $2040
  • · Z (S) $2040

1926.451 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 16, 2013
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:       (a) Jobsite:  On or about April 5, 2013, employees were working form a tubular welded frame scaffold and they were not protected from falling.  The crossbracing served only as a midrail and there was no top rail on the guardrail system.  The employees were exposed to a fall of approximately 14 feet to the ground.
Recent events (3)
  • · F (S) $816
  • · C (S) $1360
  • · Z (S) $1360

View Stevenson Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338996226.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.