Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FREEDOM FENCE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FREEDOM FENCE, INC. in 1810 JESTER DRIVE, CORSICANA, TX 75109 (NAICS 326199). OSHA activity number 338996713.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Freedom Fence, INC. for free Get an email when a new federal OSHA severe-injury report for Freedom Fence, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FREEDOM FENCE, INC.
Site address
1810 JESTER DRIVE
City
CORSICANA
State
TX
ZIP
75109
Mailing
1810 JESTER DRIVE, CORSICANA, TX 75109
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
27
Ownership type
A

6 citations on file for this inspection.

1910.133 A01

Serious Gravity 10 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:   a) On or about April 9, 2013, in the Router department, an employee operating the CNC Pro 400 router, was not wearing eye protection, exposing employees to the hazard of struck by flying particles.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   a) On or about April 9, 2013, in the shipping department, the employees driving the Caterpillar 4750 pound forklift, serial number AT81T00610, model C3000, and the Yale 3500 pound forklift, were not trained, exposing employees to the hazard of being struck by the lift.
Recent events (2)
  • · I (S) $2520
  • · Z (S) $4200

1910.178 P01

Serious Gravity 5 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)  a) On or about April 9, 2013, in the shipping/receiving area, the seat on the Yale 3500 pound forklift, serial number A809N22575, needed to be replaced/repaired, exposing employees to ergonomics hazards.  b) On or about April 9, 2013, in the shipping/receiving area, the left headlight was not working on the Caterpillar forklift, model C3000, exposing employees to the hazard of being struck by the lift.
Recent events (2)
  • · I (S) $2520
  • · Z (S) $4200

1910.305 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed:   (a)  On or about April 9, 2013, in the extruder department, the employer did not ensure the electrical junction box with exposed wires had a cover plate, exposing employees to the hazard of electrical shock.   b)  On or about April 9, 2013, in the compressor room, no cover was provided over the electrical control panel box, esposing employees to the hazard of electrical shock.
Recent events (2)
  • · I (S) $2520
  • · Z (S) $4200

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) On or about April 9, 2013, there was no hazard communications program developed or maintained, when employees are using chemicals such as, but not limited to, the Polyone EXPL 7003 Beige, and the Polyone GEONE 1540 White, exposing employees to the hazard of skin irritations.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    (a) On or about April 9, 2013, the Amerex fire extinguisher was not identified, exposing employees to the hazard of fire.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Freedom Fence, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338996713.