ORLANDO, FL ·
OSHA Inspection: PVH CORP., DELAWARE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PVH CORP., DELAWARE in 7445 EXCHANGE DRIVE, ORLANDO, FL 32809 (NAICS 493110). OSHA activity number 338996846.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PVH CORP., DELAWARE
- Site address
- 7445 EXCHANGE DRIVE
- City
- ORLANDO
- State
- FL
- ZIP
- 32809
- Mailing
- 7445 EXCHANGE DRIVE, ORLANDO, FL 32809
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 80
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 17, 2013
- Abate by
- Aug 5, 2013
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to Fall Hazards. a. On or about 04/09/2013, at the warehouse - employees were exposed to a fall hazard, in that, they were required to move items to and from racks using A-frame ladders, and they were required to carry items while ascending and descending the A-frame ladders. b. On or about 05/28/2013, at the warehouse - employees were exposed to a fall hazard, in that, the casters were not locked on the mobile ladder stand platform and the ladders were moved while employees were still standing on the mobile ladder stand platforms. c. On or about 05/28/2013, at the warehouse - employees were exposed to fall hazard, in that, they were allowed to work from the mobile ladder stand platform that were not equipped with intermediate rails that were mid-way from the top rail or if chains were used as rails they were not latch or it was mid-way from the top guard rail to the top of the platform.
Recent events (2)
- · I (S) $2400
- · Z (S) $4000
1910.23 C01
- Issued
- Jul 17, 2013
- Abate by
- Aug 5, 2013
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a. On or about 04/09/2013, at the warehouse - employees working in the truck docking area for receiving were exposed to a 4 feet fall hazard, in that, when a truck is at the dock the single plastic chain is removed creating a large opening in the floor
Recent events (2)
- · I (S) $2400
- · Z (S) $4000
1910.23 E01
- Issued
- Jul 17, 2013
- Abate by
- Aug 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a. On or about 04/09/2013, at the warehouse - employees working in the truck docking area for receiving were exposed to a 4 feet fall hazard, in that, a single plastic chain is as top guard rails and there is no intermediate guard rail.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.37 A03
- Issued
- Jul 17, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a. On or about 04/09/2013, at the warehouse - the exit door access on the rear of the warehouse was less than 28 inches caused by the obstruction of various items such as merchandise boxes and baker's rack carts. b. On or about 04/09/2013, at the warehouse - the route on the rear of the warehouse leading to the exit door was less than 28 inches caused by the obstruction of various items such as a baker's rack cart, a flexible conveyor and a trash can. c. On or about 04/09/2013, at the warehouse - the exit door on the rear of the warehouse was obstructed with various items such as merchandise boxes and baker's rack carts. d. On or about 04/09/2013, at the warehouse - many aisles in the warehouse area had a dead end and were surrounded by racking loaded with combustible clothing items. e. On or about 04/09/2013, at the warehouse - the route at the rear of the warehouse leading to the exit door was obstructed with various items such as a baker's rack cart, a flexible conveyor and a trash can.
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.157 C01
- Issued
- Jul 17, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a. On or about 04/09/2013, at the warehouse - the paths to various fire extinguishers were obstructed and fire extinguishers were not readily accessible. b. On or about 04/09/2013, at the expansion area - the fire extinguisher near the rest rooms was not identified.
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.157 G01
- Issued
- Jul 17, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a. On or about 04/09/2013, at the warehouse - employees required to extinguish incipient stage fires were exposed to fire related hazards, in that, they have not been trained to use fire extinguishers.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1904.40 A
- Issued
- Jul 17, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $1,000 · Current $600 Reduced
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a. On or about 04/09/2013, at the warehouse - the OSHA Form 300 or equivalent form for calendar years 2012 and 2013 were not provided within four (4) business hours.
Recent events (2)
- · I (O) $600
- · Z (O) $1000
1910.37 A04
- Issued
- Jul 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a. On or about 04/09/2013, at the warehouse - there was one emergency fire alarm pull down switch box that the path was obstructed by a pallet jack.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 G01 I A
- Issued
- Jul 17, 2013
- Abate by
- Jul 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a. On or about 04/09/2013, at the warehouse - various electric panels were obstructed by rolling clothing racks and trash cans and were not readily accessible.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 493110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338996846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.