THOMASTON, ME ·
OSHA Inspection: DICAPERL MINERALS CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DICAPERL MINERALS CORP. in 94 BUTTERMILK LANE, THOMASTON, ME 04861 (NAICS 327992). OSHA activity number 338997414.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DICAPERL MINERALS CORP.
- Site address
- 94 BUTTERMILK LANE
- City
- THOMASTON
- State
- ME
- ZIP
- 04861
- Mailing
- 94 BUTTERMILK LANE, THOMASTON, ME 04861
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327992
- Employees
- 15
- Ownership type
- Private (A)
Citations
16 citations on file for this inspection.
1910.27 B07
- Issued
- Sep 24, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.27(b)(7): Metal ladders and appurtenances were not painted or otherwise treated to resist corrosion and rusting when location demands. Silo #1 - The rusting 83' fixed ladder leading to the top of the silo was not painted or otherwise treated to resist corrosion and rusting. Employees were utilizing double lanyards to hook on and off the ladder to ascend and descend the fixed ladder when required to perform tasks at the top of the silo.
Recent events (2)
- · I (S) $3430
- · Z (S) $4900
1910.178 A04
- Issued
- Sep 24, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. Operating Floor - The employees used the two following unapproved forklift attachments at the facility in order to access elevated work locations: a) a wooden pallet and b) a fabricated stand.
Recent events (2)
- · I (S) $3430
- · Z (S) $4900
1910.178 Q01
- Issued
- Sep 24, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition shall be removed from service. All repairs shall be made by authorized personnel. Operating Floor - The Caterpillar forklift, serial #AT31B50620, had a defective horn.
Recent events (2)
- · I (S) $3430
- · Z (S) $4900
1910.219 C02 I
- Issued
- Sep 24, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: In the following instances, horizontal shafts were not enclosed. a) Operating Floor - The horizontal rotating shaft to the mill draft fan was not enclosed. b) Operating Floor - The horizontal rotating shaft to the pod fan was not enclosed.
Recent events (2)
- · I (S) $2450
- · Z (S) $3500
1910.219 D01
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): In the following instances, the pulleys were inadequately guarded: a) Operating Floor - The pulleys to the pod fan motor were inadequately guarded. b) Operating Floor - The pulleys to the mill draft fan were inadequately guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 E03 I
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: In the following instances, inclined belts were not enclosed: a) Operating Floor - The inclined belts to the pod fan motor were not enclosed. b) Operating Floor - The inclined belts to the mill draft fan were not enclosed.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 C04 II
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: Operating Floor - The retaining cyclone rotating shaft end turning the chain and sprocket assembly had an exposed keyway that was not fully enclosed.
Recent events (2)
- · I (S) $2450
- · Z (S) $3500
1910.219 F03
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets. In the following instances, chain and sprocket assemblies were inadequately guarded or unguarded: a) Operating Floor - The chain and sprocket to the retaining cyclone motor were inadequately guarded. b) Operating Floor - The chain and sprocket to the portable bag press were not guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B03
- Issued
- Sep 24, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.303(b)(3): Insulation integrity. Completed wiring installations shall be free from short circuits and from grounds other than those required or permitted by this subpart. Operating Floor - The 480 volt - 3 phase plug used to energize the 1 ton electrical hoist had a loose, ungrounded wire that damaged the two ungrounded conductor prongs through the arcing effects of a short circuit.
Recent events (2)
- · I (S) $3430
- · Z (S) $4900
1910.23 C01
- Issued
- Sep 24, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $56,000 · Current $39,200 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides, Operating floor - An employee was elevated by a forklift while standing on a wooden pallet, approximately 14' above the floor, without any fall protection in order to adjust the system damper.
Recent events (2)
- · I (W) $39200
- · Z (W) $56000
1910.134 C02 I
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Plant Wide - The employer did not provide training in accordance to Appendix D for employees who used the Moldex 2200 N95 filtering face masks.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.146 C01
- Issued
- Sep 24, 2013
- Abate by
- Dec 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces. At the Plant - The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 E02
- Issued
- Sep 24, 2013
- Abate by
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly. In the following instances, fire extinguishers had not been visually inspected on a monthly basis. a) Operating Floor - The fire extinguisher between the bathroom and break room door was not visually inspected. b) Plant Manager's Office - The fire extinguisher was not visually inspected.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- Sep 24, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. In the following instances, equipment were not installed and used in accordance with their listing and labeling: a) Operating Floor - The 480 volt three phase mill and pod control panels were not installed in accordance to their listing or labeling in that three latches to keep the doors from opening were missing. b) Operating Floor - Two extension cords plugged together with general use cord caps were lying in water.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G02 III
- Issued
- Sep 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. Operating Floor - The yellow extension cord on the floor did not have strain relief at the female end of the plug.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.334 A02 I
- Issued
- Sep 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): In the following instances, portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects: a) Operating Floor - The 120 volt cord to toggle switch was missing a grounding pin. b) Operating Floor - The red/black extension cord had damaged outer insulation exposing the conductors to damage.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Dicaperl Minerals Corp.
View Dicaperl Minerals Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 327992)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338997414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.