Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ROKO HOLDINGS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ROKO HOLDINGS, LLC in 240 6TH STREET NW, MASSILLON, OH 44647 (NAICS 562920). OSHA activity number 338998578.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roko Holdings, LLC for free Get an email when a new federal OSHA severe-injury report for Roko Holdings, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ROKO HOLDINGS, LLC
Site address
240 6TH STREET NW
City
MASSILLON
State
OH
ZIP
44647
Mailing
PO BOX 2103, MOBILE, AL 36652
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562920
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On and before April 9, 2013, company employees were required to service equipment including, but not limited to; saws, air compressors, dip tanks, and a Wheelabrator. The company did not establish an energy control program.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On and before April 9, 2013, machine specific energy control procedures were not developed for equipment including, but not limited to; saws, air compressors, dip tanks, and a Wheelabrator, that is serviced in the facility.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On and before April 9, 2013, company employees worked with and around chemicals including, but not limited to; potassium hydroxide, hydrochloric acid, and silica. The company had not developed and implemented a hazard communication program.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.1200 F06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  On or about April 9, 2013, tanks containing chemicals including, but not limited to, potassium hydroxide and hydrochloric acid were not labeled.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On and before April 9, 2013, company employees worked with and around chemicals including, but not limited to; potassium hydroxide, hydrochloric acid, and silica. Employees have not received hazard communication training.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338998578.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.