GROVELAND, FL ·
OSHA Inspection: SMITH ROOFING OF CLERMONT, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SMITH ROOFING OF CLERMONT, INC in 8000 CHERRY RD, GROVELAND, FL 34736 (NAICS 238160). OSHA activity number 338998594.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SMITH ROOFING OF CLERMONT, INC
- Site address
- 8000 CHERRY RD
- City
- GROVELAND
- State
- FL
- ZIP
- 34736
- Mailing
- 284 W MINNEOLA AVE, CLERMONT, FL 34711
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- May 3, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) front of house - roof - employees were exposed to a fall of 12 feet 7 inches while installing metal shingles. The slope of the roof was 4/12 and 6/12, on or about 4/10/13.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1926.1053 B01
- Issued
- May 3, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Front of house - the employees were exposed to a fall of 10 feet 10 inches, in that, they were using a folding ladder that extended only a couple of inches above the landing, on or about 4/10/13.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1926.1053 B09
- Issued
- May 3, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: (a) front of house - roof - the employees were exposed to a fall of 10 feet 10 inches, in that, metal roofing shingles and a wood slide guard were stored directly at the top of the ladder landing area, on or about 4/10/13.