Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: SESSER CONCRETE PRODUCTS COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SESSER CONCRETE PRODUCTS COMPANY in 910 SOUTH COCKRUM STREET, SESSER, IL 62884 (NAICS 327331). OSHA activity number 338998768.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sesser Concrete Products Company for free Get an email when a new federal OSHA severe-injury report for Sesser Concrete Products Company is published. One employer, no account, unsubscribe in one click.
Site address
910 SOUTH COCKRUM STREET
City
SESSER
State
IL
ZIP
62884
Mailing
910 SOUTH COCKRUM STREET, SESSER, IL 62884
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327331
Employees
6
Ownership type
Private (A)

12 citations on file for this inspection.

1910.215 A02

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1910.215(a)(2):       Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:       a) In the Main Production Building, northeast section, on the Baldor 1/3 HP bench grinder, right side, the guard to cover the end spindle nut was missing.
Recent events (2)
  • · I (S) $650
  • · Z (S) $1200

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4):     Grinding machinery was not used with work rest(s) to support offhand grinding work:    a) In the Main Production Building, northeast section, on the Baldor 1/3 HP bench grinder, on both sides, the work rests were missing.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:     a) In the Main Production Building, northwest section, on the Baldor 1/3 HP bench grinder, on both sides, the tongue guards were missing.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $1,600 · Current $900 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:       a) In the Main Production Building, northeast section, one acetylene cylinder was stored standing next to four oxygen cylinders.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1600

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1910.305(b)(2)(i):       All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.        a) In the Main Production Building, northeast section, east wall, the 110 volt electrical receptacle was missing its faceplate, exposing the inner electrical wiring connections.
Recent events (2)
  • · I (S) $650
  • · Z (S) $1200

1910.334 A02 I

Serious Gravity 1 2 instances 3 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1910.334(a)(2)(i):       Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):       a)    In the Main Production Building, northeast section, east wall, the yellow 110 volt electrical extension cord receptacle supplying electricity various equipment , had damage/openings  in its outer insulation.  The outer insulation also was pulled away from plug, allowing strain to be placed the inner electrical connectors.        b)    Outside, north of the Production Building, on the fuel tanks, the orange 110 volt extension cord outer insulation  was pulled away from plug, allowing strain to be placed the inner electrical connectors.  It was spliced together with wing nuts.
Recent events (2)
  • · I (S) $650
  • · Z (S) $1200

1910.1200 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Aug 12, 2013
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1910.1200(e)(1):         Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):                 a)    A written Hazard Communications program regarding hazardous chemicals had not been developed to inform and train employees to protect them from chemicals hazards.  Employees working with hazardous chemicals  such as but not limited to motor brake fluid, hydraulic oil and cement were exposed to the hazards associated with those products.
Recent events (2)
  • · I (S) $650
  • · Z (S) $1200

1910.1200 G01

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1):      The employer did not have a material safety data sheet for each hazardous chemical:         a)    Material safety data sheets were not kept that would provide information in case of a medical emergency or condition if an employee ingested or contacted chemicals.  Employees working with hazardous chemicals  such as but not limited to motor brake fluid, hydraulic oil and cement were exposed to the hazards associated with those products.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):         Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets.                a)    Employees had not been trained regarding the hazards related with using hazardous chemicals  such as but not limited to motor brake fluid, hydraulic oil and cement were exposed to the hazards associated with those products.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H02 I

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2)(i): The employer did not provide information to the employees on the requirements of the Hazard Communication Standard 29 CFR 1910.1200:    a)  Employees were exposed to hazards due to exposure to working with cement and hazardous chemicals such as but not limited to mobile equipment oils, brake fluid, and hydraulic fluids.  The employer did not provide employee information on these chemicals to include the physical and health hazards associated with them
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H03

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv):    a)    Employees had not been trained regarding the hazards related with using hazardous chemicals such as but not limited to  motor brake fluid, hydraulic oil and cement were exposed to the hazards associated with those products.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Jun 20, 2013
Abate by
Aug 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):       The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l):       a)    Employees were exposed to hazards associated with the potential  unsafe operation of powered industrial vehicles.  The employer had not certified all operators performing forklift operations had been trained and were competent to run the trucks in a safe manner.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Sesser Concrete Products Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338998768.