Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: OR ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OR ROOFING in 231 THEATER DRIVE, DUNCANSVILLE, PA 16635 (NAICS 238120). OSHA activity number 338998990.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Or Roofing for free Get an email when a new federal OSHA severe-injury report for Or Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
OR ROOFING
Site address
231 THEATER DRIVE
City
DUNCANSVILLE
State
PA
ZIP
16635
Mailing
105 CHESTNUT HILL COURT, HENDERSONVILLE, NC 28792
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
8
Ownership type
Private (A)

2 citations on file for this inspection.

1926.760 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 17, 2013
Abate by
Apr 17, 2013
Penalty
Initial $2,800 · Current $1,002 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:     (a) Jobsite, Theater Drive, Duncansville, PA:  On or about 04/09/13 an employee was working at the edge of the roof operating a crimper without any fall protection systems in place.  This condition exposed the employee to fall hazards of approximately 27 feet to the ground below.
Recent events (2)
  • · I (S) $1002
  • · Z (S) $2800

1926.761 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 17, 2013
Abate by
Apr 17, 2013
Penalty
Initial $1,200 · Current $1,002 Reduced
29 CFR 1926.761(b)(2): The employer did not provide a training program that included the use and operation of guardrail systems (including perimeter safety cable systems), personal fall arrest systems, positioning device systems, fall restraint systems, safety net systems, and other protection to be used:      (a) Jobsite, Theater Drive, Duncansville, PA:  On or about 04/09/13 an employee was operating a crimper at the edge of the roof area without utilizing fall protection exposing the employee to a 27 foot fall hazard.  The employee had not been trained to recognize and understand when fall protection systems were necessary to protect themselves' when performing steel erection activities.
Recent events (2)
  • · I (S) $1002
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338998990.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.