NEWNAN, GA —
OSHA Inspection: EDGAR ORTIZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDGAR ORTIZ in 33 VALENCIA LANE, NEWNAN, GA 30263 (NAICS 238170). OSHA activity number 338999816.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDGAR ORTIZ
- Site address
- 33 VALENCIA LANE
- City
- NEWNAN
- State
- GA
- ZIP
- 30263
- Mailing
- 3925 SATELLITE BLVD. APT. 125, DULUTH, GA 30096
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a): South side under work bench, new residential construction located at 33 Valencia Lane, Newnan, GA 30263: Employees were exposed to electrical shock hazards while using an electrical junction box which was connected to a flexible cord and used as makeshift power outlet. The junction box used is intended for indoor use and is manufactured to be fixed to support within a structure.
Recent events (1)
- — Z (S) $1600
1926.405 B02
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: (a) South side under work bench, new residential construction located at 33 Valencia Lane, Newnan, GA 30263: Employees were exposed to electrical shock hazards while using an energized junction box which was not provided with a cover over the outlets.
Recent events (1)
- — Z (S) $1600
1926.451 C02
- Issued
- May 30, 2013
- Abate by
- Jun 11, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) South gable side, new residential construction located at 33 Valencia Lane, Newnan, GA 30263: Employees were exposed to fall hazards while working on a pump jack scaffold system which was not being supported on a firm foundation as the supports were not resting on mud sills or base plates.
Recent events (1)
- — Z (S) $2800
1926.451 G04 I
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. (a) South gable side, new residential construction located at 33 Valencia Lane, Newnan, GA 30263: Employees were exposed to fall hazards while installing Hardie-Plank Siding at heights of 17-feet, 9-inches on a pump jack scaffold platform which was missing mid and end guardrails as no other fall protection system was used to prevent falls to lower levels.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- May 30, 2013
- Abate by
- Jun 11, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a) South gable side, new residential construction located at 33 Valencia Lane, Newnan, GA 30263: The support poles of the Alum-A-Pole Pump Jack Scaffold System were not secured at the bottom of the poles to prevent displacement while employees worked at heights of approximately 17-feet, 9-inches installing Hardie-Plank Siding.
Recent events (1)
- — Z (S) $2800
More inspections at Edgar Ortiz
View Edgar Ortiz's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338999816.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.