OSHA Inspection: SPECIALTY PROMOTIONS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPECIALTY PROMOTIONS, INC. in 6250 W. HOWARD ST. 6019 W. HOWARD ST., NILES, IL 60714 (NAICS 323110). OSHA activity number 338999964.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Specialty Promotions, INC. — free Get an email when a new federal OSHA severe-injury report for Specialty Promotions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6250 W. HOWARD ST. 6019 W. HOWARD ST.
City
NILES
State
IL
ZIP
60714
Mailing
6019 W. HOWARD ST., NILES, IL 60714
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
330
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2013
Abate by
Apr 24, 2013
Penalty
Initial $2,890 · Current $2,000 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) Inkjet/Bindery Area with Dryers - The floor area had flexible cords laying across the walking surface and was not kept clean and orderly.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2890

1910.178 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2013
Abate by
May 20, 2013
Penalty
Initial $3,400 · Current $2,202 Reduced
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging area was not protected from damage by trucks:      (a) Building 6250 / Storage Area - The VFroce battery charging apparatus was not protected by location or a physical barrier guard to prevent physical damage by fork lift trucks.     In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2202
  • — Z (S) $3400

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 24, 2013
Abate by
Apr 24, 2013
Penalty
Initial $3,613 · Current $2,248 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):        (a) Building 6019/ Stitching Area- The physical barrier guard on the two Harris - AM Graphics Stitchers would not prevent entry of hands into the point of operation.  The machines interlock devices did not work in order to prevent the machines from operating while the guards were opened.      (b) Building 6250 / Bailer Area - The sliding barrier door on the bailer would not prevent entry of hands into the point of operation.  The machine had an interlock device that failed to stop the machine from operating when the door was opened.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2248
  • — Z (S) $3613

1910.303 G01 II

Other-than-serious 4 instances 1 exposed
Issued
Apr 24, 2013
Abate by
May 20, 2013
Penalty
Initial $850 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:      (a) Facility Wide / Plant Floor Area / Laser Print Room / Kurt Rugger Tabbing machine area / Imaging Area - The required working space about electrical panels including but not limited to RP-2, PP-A, PP-5, and PP-DM was used for storage of various materials including but not limited to a ladder, boxes, and tables.       In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (O) $850

View Specialty Promotions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338999964.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.