OSHA Inspection: M & Y HOME IMPROVEMENT, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M & Y HOME IMPROVEMENT, INC in 711 BELLEVUE AVE, WORCESTER, MA 01610 (NAICS 238170). OSHA activity number 339000879.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & Y Home Improvement, INC for free Get an email when a new federal OSHA severe-injury report for M & Y Home Improvement, INC is published. One employer, no account, unsubscribe in one click.
Site address
711 BELLEVUE AVE
City
WORCESTER
State
MA
ZIP
01610
Mailing
5 MCFARLAND CT #N2, WORCESTER, MA 01604
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2013
Abate by
May 13, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:   (a) 711 Bellevue Ave Worcester, MA: On or about April 5, 2013, an employee was observed working on the roof of this residence without any fall protection more than 22 FT above the ground below which is not in accordance with this subpart:   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
May 7, 2013
Abate by
May 13, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:    (a) 711 Bellevue Ave Worcester, MA: On or about April 5, 2013, an employee was observed climbing a ladder that did not extend the required 3 FT past the roof surface he was accessing to reach his work space which is not in accordance with this subpart.