Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AF SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AF SUPPLY in 942 LAFAYETTE AVENUE, BROOKLYN, NY 11221 (NAICS 423720). OSHA activity number 339001802.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AF Supply for free Get an email when a new federal OSHA severe-injury report for AF Supply is published. One employer, no account, unsubscribe in one click.
Establishment
AF SUPPLY
Site address
942 LAFAYETTE AVENUE
City
BROOKLYN
State
NY
ZIP
11221
Mailing
942 LAFAYETTE AVENUE, BROOKLYN, NY 11221
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423720
Employees
30
Ownership type
Private (A)

12 citations on file for this inspection.

1910.22 B01

Other-than-serious 1 instance 6 exposed
Issued
Aug 2, 2013
Abate by
Aug 21, 2013
Penalty
Initial $2,700 · Current $1,250 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repairs, with no obstruction across or in aisles that could create a hazard.    Location:     942 Lafayette Avenue, Brooklyn, NY. Basement Floor.    Passageways were not maintained and kept clear with no obstructions across or in aisles that could create a hazard. Floors were not kept in good repair.  On or about 04/9/2013.
Recent events (2)
  • · I (O) $1250
  • · Z (S) $2700

1910.36 A03

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 2, 2013
Penalty
Initial $4,500 · Current $6,000
29 CFR 1910.36(a)(3): Openings into an exit must be limited. An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace, or to the exit discharge. An opening into an exit must be protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a nationally recognized testing laboratory. Section 1910.155(c)(3)(iv)(A) of this part defines "listed" and �� 1910.7 of this part defines a "nationally recognized testing laboratory."      Location:    942 Lafayette Avenue, Brooklyn, NY.       a) Throughout the establishment, approximately three emergency doors were kept propped open. On or about 4/9/2013.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $4500

1910.36 D01

Serious Gravity 10 1 instance 7 exposed
Issued
Aug 2, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.       Location: 942 Lafayette Avenue, Brooklyn, NY. Staircase leading to Van Buren Street.    a) The emergency exit door was locked from the inside with keys and could not be open without using a key. On or about 07/11/2013.
Recent events (2)
  • · I (S) $0
  • · Z (S) $6300

1910.141 A03 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 2, 2013
Abate by
Aug 14, 2013
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed.   Location:    942 Lafayette Avenue, Brooklyn, NY.    a)    Employees restrooms were not kept clean and in an orderly fashion. On or about 04/9/2013.
Recent events (2)
  • · I (O) $1500
  • · Z (S) $2700

1910.141 D02 II

Other-than-serious 1 instance 4 exposed
Issued
Aug 2, 2013
Abate by
Aug 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Each lavatory shall be provided with hot and cold running water, or tepid running water.    Location:    942 Lafayette Avenue, Brooklyn, NY.    a) Employees restrooms were not provided with hot or tepid running water. On or about 04/09/2013.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 2, 2013
Penalty
Initial $3,600 · Current $2,500 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.    Location:   942 Lafayette Avenue, Brooklyn, NY. Battery Charging Station.      a) Employees are exposed to injurious corrosive materials such as, but not limited to electrolyte solutions and an eyewash is not provided. On or about 4/9/2013.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3600

1910.157 C01

Other-than-serious 1 instance 6 exposed
Issued
Aug 2, 2013
Abate by
Aug 14, 2013
Penalty
Initial $2,700 · Current $1,250 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.    Location:    942 Lafayette Avenue, Brooklyn, NY.    Employer did not ensure that the portable fire extinguishers were mounted. On or about 04/9/2013.
Recent events (2)
  • · I (O) $1250
  • · Z (S) $2700

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 2, 2013
Abate by
Aug 21, 2013
Penalty
Initial $3,600 · Current $2,500 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    Location:   942 Lafayette Avenue, Brooklyn  NY.    a) Employees operating the power industrial truck without being certified and not trained. On or about 03/14/2013.      Abatement Note:    The certification shall include:    1.    The name of the operator.  2.    The date of the training.  3.    The date of the evaluation; and  3.    The identity of the person(s) performing the training or evaluation.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3600

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 2, 2013
Abate by
Aug 14, 2013
Penalty
Initial $3,600 · Current $3,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    Location:  942 Lafayette Avenue, Brooklyn, NY. Loading dock.    a)    An electric panel board was not legibly marked to indicate the purpose of each switch on the panel board in the establishment. On or about 4/9/2013.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3600

1910.304 F01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Overcurrent devices shall be readily accessible to each employee or authorized building management personnel. These overcurrent devices may not be located where they will be exposed to physical damage or in the vicinity of easily ignitable material.  Location:    942 Lafayette Avenue, Brooklyn, NY. Loading dock.  a)    Electrical panel boxes located in an open electrical hallway area, rated 240/120 volt were not maintained free of storage materials. The area had boxes, trash can On or about 04/09/2013.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 2, 2013
Abate by
Aug 14, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    Location:    942 Lafayette Avenue, Brooklyn, NY. Basement Ceiling.      a) An electrical junction box was not provided with a cover and live electrical wires inside the box were exposed. On or about 04/09/2013.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3600

1904.32 B06

Other-than-serious 1 instance 30 exposed
Issued
Aug 2, 2013
Penalty
Initial $900 · Current $500 Reduced
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1st and April 30th.     Location:    Establishment.    The Summary of Work-Related Injuries and Illnesses of OSHA Form 300A for the calendar year 2012 was not posted. On or about 04/09/2013.
Recent events (2)
  • · I (O) $500
  • · Z (O) $900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339001802.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.