Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: CINCON CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CINCON CONSTRUCTION in 2754 HYLAN BLVD, STATEN ISLAND, NY 10306 (NAICS 238140). OSHA activity number 339002396.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cincon Construction for free Get an email when a new federal OSHA severe-injury report for Cincon Construction is published. One employer, no account, unsubscribe in one click.
Establishment
CINCON CONSTRUCTION
Site address
2754 HYLAN BLVD
City
STATEN ISLAND
State
NY
ZIP
10306
Mailing
5507-10 NESCONSET HWY, MOUNT SINAI, NY 11766
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 18, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:  A) 2754 Hylan Blvd, Staten Island, NY 10306: Employees were exposed to fall hazard of approximately 148  due to missing planking at the rear of the scaffold on the first and second levels.  Condition observed on or about April 8, 2013.
Recent events (1)
  • · Z (S) $2800

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1):  For scaffold platforms more than two feet above or below a point of access, portable ladders, hook on ladders, attachable ladders, ramps, walkways. Integral prefabricated scaffold access or direct access from another scaffold, structure, personal hoist, or similar surface was not used:  A) 2754 Hylan Blvd, Staten Island, NY 10306: Employees were exposed to fall hazards of approximately 14' 8" to the ground below when a ladder was not provided for safe access to a tubular welded scaffold platform.  Condition observed on or about April 8, 2013.
Recent events (1)
  • · Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:   A) 2754 Hylan Blvd, Staten Island, NY 10306:  Employees were exposed to fall hazards of approximately 14' 8" from the tubular welded scaffold platform in which a fall protection system was not erected or used by employees engaged in stucco refinishing activities.  Condition observed on or about April 8, 2013.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339002396.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.