ENCINO, TX —
OSHA Inspection: OCCIDENTAL OIL & GAS CORPORATION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of OCCIDENTAL OIL & GAS CORPORATION in LOPEZ WELL #11, RIGG 399, ENCINO, TX 78353 (NAICS 213112). OSHA activity number 339003063.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OCCIDENTAL OIL & GAS CORPORATION
- Site address
- LOPEZ WELL #11, RIGG 399
- City
- ENCINO
- State
- TX
- ZIP
- 78353
- Mailing
- P.O. BOX 4294, HOUSTON, TX 77210
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 1
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 30, 2013
- Abate by
- Nov 14, 2013
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential sudden and unexpected release of pressure during stump testing of a blow-out preventer: On or about April 1, 2013 at Helmrich and Payne Rig #399 employees were exposed to struck-by hazards while stump testing the blow-out preventer at 10,000 pounds and the auto clave connector failed, unexpectedly releasing approximately 10,000 pounds of pressure. A. Evaluation and assessment of the port into which an autoclave connector would be threaded into was not conducted to ensure the threads of the male and female fittings were of the proper size and configuration. B. The type, pressure rating, size, and end connections for each piece of equipment to be used or tested, as documented by permanent markings on the equipment or by records that are traceable was not verified prior to the initiation of testing the blow-out preventer. C. An adequate buffer zone restricting the direction of movement by personel into and near the area where the blow-out preventer was being tested was not established and marked.
Recent events (1)
- — Z (S) $7000
More inspections at Occidental OIL & GAS Corporation
View Occidental OIL & GAS Corporation's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339003063.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.