Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OCCIDENTAL OIL & GAS CORPORATION

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of OCCIDENTAL OIL & GAS CORPORATION in LOPEZ WELL #11, RIGG 399, ENCINO, TX 78353 (NAICS 213112). OSHA activity number 339003063.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Occidental OIL & GAS Corporation — free Get an email when a new federal OSHA severe-injury report for Occidental OIL & GAS Corporation is published. One employer, no account, unsubscribe in one click.
Site address
LOPEZ WELL #11, RIGG 399
City
ENCINO
State
TX
ZIP
78353
Mailing
P.O. BOX 4294, HOUSTON, TX 77210
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
1
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 30, 2013
Abate by
Nov 14, 2013
Penalty
Initial $7,000 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential sudden and unexpected release of pressure during stump testing of a blow-out preventer:  On or about April 1, 2013 at Helmrich and Payne Rig #399 employees were exposed to struck-by hazards while stump testing the blow-out preventer at 10,000 pounds and the auto clave connector failed, unexpectedly releasing approximately 10,000 pounds of pressure.    A. Evaluation and assessment of the port into which an autoclave connector would be threaded into was not conducted to ensure the threads of the male and female fittings were of the proper size and configuration.  B. The type, pressure rating, size, and end connections for each piece of equipment to be used or tested, as documented by permanent markings on the equipment or by records that are traceable was not verified prior to the initiation of testing the blow-out preventer.  C. An adequate buffer zone restricting the direction of movement by personel into and near the area where the blow-out preventer was being tested was not established and marked.
Recent events (1)
  • — Z (S) $7000

View Occidental OIL & GAS Corporation's full OSHA safety record →