Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PATTERSON UTI, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of PATTERSON UTI, LLC in STILES 16 #15-16H RIG #344, WHEELER, TX 79096 (NAICS 213111). OSHA activity number 339003576.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Patterson UTI, LLC for free Get an email when a new federal OSHA severe-injury report for Patterson UTI, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PATTERSON UTI, LLC
Site address
STILES 16 #15-16H RIG #344
City
WHEELER
State
TX
ZIP
79096
Mailing
450 GEARS ROAD, SUITE 500, HOUSTON, TX 77067
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
13
Ownership type
Private (A)

2 citations on file for this inspection.

1910.303 B01

Serious Gravity 5 5 instances 14 exposed
Issued
May 28, 2013
Abate by
Jul 8, 2013
Penalty
Initial $4,675 · Current $2,805 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):    MOBILE HOME/OFFICES: On or about March 6, 2013, the employer did not ensure that extension cords powering equipment such as, but not limited to, sump pumps servicing the mobile homes were inspected and taken out of service when a defect or damage was observed. Employees were exposed to hazards associated with electrical shock, burns and arcing.
Recent events (2)
  • · I (S) $2805
  • · Z (S) $4675

1910.304 G05

Deleted Serious Gravity 5 4 instances 14 exposed
Issued
May 28, 2013
Abate by
Jun 14, 2013
Penalty
Initial $4,675 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about March 6, 2013, the employer did not ensure that mobile home/office trailers and/or related equipment were properly grounded. Employees were exposed to hazards associated with electrical shock, burns and arcing.