Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRYAN CONTAINER COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BRYAN CONTAINER COMPANY, INC. in 1121 TURKEY CREEK RD, BRYAN, TX 77801 (NAICS 326199). OSHA activity number 339003592.

Watch Bryan Container Company, INC. — free Get an email when a new federal OSHA severe-injury report for Bryan Container Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1121 TURKEY CREEK RD
City
BRYAN
State
TX
ZIP
77801
Mailing
1121 TURKEY CREEK RD, BRYAN, TX 77801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
15
Ownership type
A

12 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.22(a)(2):  The floor of every workroom was not maintained in a clean and, so far as possible, dry condition.  Where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided when practicable:    On or about April 5, 2013 and at times prior thereto, the bin washing area was not kept clean and drainage of the pit was not maintained, resulting in stagnant water that can harbor mosquitoes and/or other pests, exposing employees to an unsanitary condition.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.23 A09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(a)(9): Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment, or walls) shall be protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securely held in place to prevent tools or materials from falling through.  On or about April 5, 2013 and at times prior thereto, the grating in the bin washing area had openings of more than 1 inch, exposing employees to the hazards of slip, trips, and falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.     On or about April 5, 2013, and at times prior thereto, the grinder operator was working near the unguarded edges of a platform without fall protection, exposing the employee(s) to fall hazards approximately 4'7" to the ground.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.95 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:     a)  A grinder operator was exposed to continuous noise at 193.3% of the permissible daily noise exposure (8-hour Time Weight Average sound level of 85 dBA) during the 347 minute sampling period on May 8, 2013.  For a full eight hour work shift this exposure would be equivalent to an average sound level of 94.8 dBA.  Exposure calculations included a zero increment for the 133 minutes not sampled.      a)  An extruder technician was exposed to continuous noise at 55.6% of the permissible daily noise exposure (8-hour Time Weight Average sound level of 85 dBA) during the 317 minute sampling period on May 8, 2013.  For a full eight hour work shift this exposure would be equivalent to an average sound level of 85.7 dBA.  Exposure calculations included a zero increment for the 163 minutes not sampled.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about May 5, 2013 and at times prior thereto, the employer did not provide employees with training on the use of a Toyota Forklift, exposing employees to the hazards of being struck by forklifts.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about May 5, 2013 and at times prior thereto, a Toyota Forklift was in operation routinely without a daily inspection performed by employees, exposing employees to the hazards of being struck by forklifts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 6 instances 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a)  On or about April 5, 2013, and at times prior thereto, employees operating a job made plastic bin cutter had an unguarded STIHL Chainsaw with a Dayton Industrial Motor, exposing employees to the hazard of being struck by the chainsaw blade.     b)  On or about April 5, 2013, and at times prior thereto, employees operating a job made Milwaukee Router Motor with a jig saw, exposing employees to the hazard of being struck by the unused portion of the blade.      c)  On or about April 5, 2013, and at times prior thereto, employees cutting plastic with a Delta Band Saw did not have the unused portion of the blade guarded, exposing employees to the hazard of being struck by the blade.       d)  On or about April 5, 2013, and at times prior thereto, employees cutting plastic with a JET Band Saw did not have the unused portion of the blade guarded, exposing employees to the hazards of being struck by the blade.      e) On or about April 5, 2013, and at times prior thereto, employees cutting plastic with a MSC Band Saw did not have the unused portion of the blade guarded, exposing employees to the hazard of being struck by the blade.     f) On or about April 05, 2013, and at times prior there to, employees operating a job made vacuum forming machine for the production of trash liners did not have guards in place to protect employees from rotating and moving parts, exposing employees to the hazards of being caught in moving parts.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.212 A05

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:   On or about April 5, 2013, and at times prior thereto, a portable fan was operating without the front blade guard installed, exposing employees of the hazards of being struck by fan blades.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 C03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy.  All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:     On or about April 5, 2013, and at times prior thereto, an industrial fan had conductors that had an unapproved splice that was not covered with a proper insulating device, exposing employees to the hazards of electrical shock.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.303 G02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):     On or about April 5, 2013, and at times prior thereto, there were exposed energized parts inside a metal quad size outlet box with a broken outlet.  The box was mounted on the bottom of a column next to the MSC bandsaw, exposing employees to the hazards of electrical shock.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   On or about April 5, 2013, and at times prior thereto, employees were not protected from inadvertent contact with energized parts of a duplex receptacle that did not have a cover.  The receptacle was located against the wall behind the dust collector.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:    a)  On or about April 5, 2013, and at times prior thereto, on the wall behind the grinder, a 480V cabinet had a knockout missing on the right bottom side of it, exposing employees to the hazards of electrical shock and fire.     b)  On or about April 5, 2013, and at times prior thereto, on the wall behind the grinder, a 208V cabinet had a knockout missing on the bottom left side of it, exposing employees to the hazards of electrical shock and fire.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600