VALHALLA, NY —
OSHA Inspection: FB1 SIDING CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FB1 SIDING CORP. in 221 COLUMBUS AVE., VALHALLA, NY 10595 (NAICS 238160). OSHA activity number 339004434.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FB1 SIDING CORP.
- Site address
- 221 COLUMBUS AVE.
- City
- VALHALLA
- State
- NY
- ZIP
- 10595
- Mailing
- 5 ANDOVER RD. APT 1, YONKERS, NY 10710
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 B01 I
- Issued
- May 10, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: on the ground below the roof on or about: 04/8/13 a) An employee was using a Homelite Blower Vac to cleanup up roofing debris. The employee was not provided with GFCI protection or an assured equipment grounding conductor program. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 B02
- Issued
- May 10, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway was not at least 18 inches (46 cm) wide: location: side lawn to driveway on or about: 4/8/13 a) An employee used a metal scaffold pic, set up between the the side lawn and the top of the dumpster, while dumping wheel barrow loads of roofing debris. The pic was only 12 inches wide. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.501 B13
- Issued
- May 10, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $14,000 · Current $7,020 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: location: roof on or about: 4/8/13 a) Employees, engaged in residential roofing, were not using any means of fall protection. The employees were exposed to a fall of 16 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (W) $7020
- — Z (W) $14000
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339004434.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.