On , OSHA opened a referral safety inspection of G. DRAKE MASONRY in 48-50 WATER STREET, EASTPORT, ME 04631 (NAICS 238140). OSHA activity number 339007072.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G. Drake Masonry — free Get an email when a new federal OSHA severe-injury report for G. Drake Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
G. DRAKE MASONRY
Site address
48-50 WATER STREET
City
EASTPORT
State
ME
ZIP
04631
Mailing
441 WESTERN AVENUE, DIXMONT, ME 04932
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.850 A

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $2,800 · Current $2,240 Reduced
29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.    Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and an engineering survey was not made by a competent person.
Recent events (2)
  • — I (S) $2240
  • — Z (S) $2800

1926.850 B

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $2,800 · Current $2,240 Reduced
29 CFR 1926.850(b): When employees are required to work within a structure to be demolished which has been damaged by fire, flood, explosion, or other cause, the walls or floor shall be shored or braced.    Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and the second floor wall, resting on the rotten timber header, was not adequately shored.
Recent events (2)
  • — I (S) $2240
  • — Z (S) $2800

1926.854 B

Serious Gravity 10 1 instance 6 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.854(b): No wall section, which is more than one story in height, shall be permitted to stand alone without lateral bracing, unless such wall was originally designed and constructed to stand without such lateral support, and is in a condition safe enough to be self-supporting. All walls shall be left in a stable condition at the end of each shift.  Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and the lateral wall bracing was not adequate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0