EASTPORT, ME —
OSHA Inspection: G. DRAKE MASONRY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of G. DRAKE MASONRY in 48-50 WATER STREET, EASTPORT, ME 04631 (NAICS 238140). OSHA activity number 339007072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G. DRAKE MASONRY
- Site address
- 48-50 WATER STREET
- City
- EASTPORT
- State
- ME
- ZIP
- 04631
- Mailing
- 441 WESTERN AVENUE, DIXMONT, ME 04932
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.850 A
- Issued
- May 6, 2013
- Abate by
- May 14, 2013
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed. Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and an engineering survey was not made by a competent person.
Recent events (2)
- — I (S) $2240
- — Z (S) $2800
1926.850 B
- Issued
- May 6, 2013
- Abate by
- May 14, 2013
- Penalty
- Initial $2,800 · Current $2,240 Reduced
General-duty citation text
29 CFR 1926.850(b): When employees are required to work within a structure to be demolished which has been damaged by fire, flood, explosion, or other cause, the walls or floor shall be shored or braced. Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and the second floor wall, resting on the rotten timber header, was not adequately shored.
Recent events (2)
- — I (S) $2240
- — Z (S) $2800
1926.854 B
- Issued
- May 6, 2013
- Abate by
- May 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.854(b): No wall section, which is more than one story in height, shall be permitted to stand alone without lateral bracing, unless such wall was originally designed and constructed to stand without such lateral support, and is in a condition safe enough to be self-supporting. All walls shall be left in a stable condition at the end of each shift. Holmes Building - On or about April 11, 2013, the facade of the building collapsed during demolition activities, and the lateral wall bracing was not adequate.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at G. Drake Masonry
View G. Drake Masonry's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339007072.