LUCEDALE, MS ·
OSHA Inspection: GEORGE COUNTY PALLETS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GEORGE COUNTY PALLETS, INC. in 6286 HWY 57 SOUTH, LUCEDALE, MS 39452 (NAICS 321920). OSHA activity number 339007692.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEORGE COUNTY PALLETS, INC.
- Site address
- 6286 HWY 57 SOUTH
- City
- LUCEDALE
- State
- MS
- ZIP
- 39452
- Mailing
- P.O. BOX 1592, LUCEDALE, MS 39452
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 10
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.212 A05
- Issued
- Jun 4, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch. (a). Eastside of shop - On or about April 11, 2013, the blowers used to circulate air in the shop area had unguarded blades.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.213 H01
- Issued
- Jun 4, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. (a). Westside of shop, radial arm saw - On or about April 11, 2013, the lower portion of the Dewalt radial arm saw blades were not guarded.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.219 D01
- Issued
- Jun 4, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. (a). Throughout shop - On or about April 11, 2013, the pulleys for the blowers, air compressor and pallet notcher were not guarded.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.303 G01
- Issued
- Jun 4, 2013
- Abate by
- Jun 4, 2013
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a). Main electrical shut off - On or about April 11, 2013, the area in front of the main electrical shut off was cluttered with discarded parts and other items.
Recent events (2)
- · I (S) $612
- · Z (S) $1020
1910.303 G02 I
- Issued
- Jun 4, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures. (a). Throughout shop - On or about April 11, 2013, the equipment circuit breakers and an electrical receptacle had exposed electrical parts. The wiring connected to the top and bottom of the circuit breakers were not covered. The circuit breakers were attached to structural poles throughout the shop.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.305 B01 I
- Issued
- Jun 4, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. (a). Throughout Shop - On or about April 11, 2013 wiring entering electrical boxes were not protected from abrasion and the openings were not effectively closed.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
More inspections in this industry (NAICS 321920)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339007692.