MENTONE, TX —
OSHA Inspection: ARCOLA DRILLING & EXPLORATION LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARCOLA DRILLING & EXPLORATION LLC in ARCOLA RIG #1 3.3 N FROM MENTONE, MENTONE, TX 79754 (NAICS 213111). OSHA activity number 339009151.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCOLA DRILLING & EXPLORATION LLC
- Site address
- ARCOLA RIG #1 3.3 N FROM MENTONE
- City
- MENTONE
- State
- TX
- ZIP
- 79754
- Mailing
- 18 AUGUSTA PINES, SPRING, TX 77389
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 10
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.23 A05
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.23(a)(5): Infrequently used pit or trap door floor opening(s) with the cover(s) removed were not constantly attended by someone or protected on all exposed sides by removable standard railings: On or about December 19, 2012 on the mud pit platfrom, employees were exposed to slip trip and fall hazards while working near exposed floor openings.
Recent events (1)
- — Z (S) $2400
1910.23 B01
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.23(b)(1): Open-sided platforms 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides. On or about December19, 2012 employees were exposed to fall hazards while working and traversing the mud pit area.
Recent events (1)
- — Z (S) $2400
1910.132 D01 I
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employees. On or about December 19, 2012 employees were exposed to chemical burn hazards while working in the mudroom with caustic chemicals without being provided the appropriate personal protective equipment.
Recent events (1)
- — Z (S) $2400
1910.151 C
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. On or about December 19,02012 employees were exposed to chemical burns while working in the mud mixing room while mixing chemicals without having been provided means for rapid eye flushing in case of emergency.
Recent events (1)
- — Z (S) $1600
1910.176 B
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse. On or about December 19, 2012 employees were exposed to crushing, caught-in, and caught-between hazards while working near pipe racks that were not secured.
Recent events (1)
- — Z (S) $2400
1910.253 B02 IV
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about December 19, 2012 employees were exposed to explosion hazards due to compressed gas cylinders being stored without protective valve covers or without protection from falling.
Recent events (1)
- — Z (S) $1600
1910.303 B01 IV
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation. On or about December 19, 2012 employees were exposed to electrical hazards while working near a frayed electrical cord.
Recent events (1)
- — Z (S) $2000
1910.303 B07 I
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about December 19, 2012 employees were exposed to electrical hazards while working in the power plant due to missing electrical panels covering breaker boxes and missing breakers.
Recent events (1)
- — Z (S) $2800
1910.304 G05
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. On or about December 19, 2012 employees were exposed to electrical hazards while working on Arcola Rig #1 due to a lack of grounding throughout the rig site.
Recent events (1)
- — Z (S) $1600
1910.305 B02 I
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about December 19, 2012 employees were exposed to electrical hazards while working in the doghouse when a receptacle was missing a faceplate (110 volt).
Recent events (1)
- — Z (S) $2400
1910.1200 G08
- Issued
- Apr 24, 2013
- Abate by
- May 4, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace. On or about December 19, 2012 employees were exposed to chemical hazards while working on due to employer not providing employees material safety data sheets for the chemicals onsite.
Recent events (1)
- — Z (S) $1200
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339009151.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.