PHILADELPHIA, PA ·
OSHA Inspection: RGB SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RGB SERVICES, LLC in 5110 MARKET ST, PHILADELPHIA, PA 19139 (NAICS 238140). OSHA activity number 339009730.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RGB SERVICES, LLC
- Site address
- 5110 MARKET ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19139
- Mailing
- 831 WELSH ROAD, PHILADELPHIA, PA 19115
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $2,520 · Current $1,764 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) 5110 Market St, Scaffold - The outrigger section of the tubular welded frame scaffold was not fully decked. Employees installing mesh for stucco were exposed to a fall hazard of approximately twenty-six (26) feet. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $1764
- · Z (S) $2520
1926.451 C02
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $2,520 · Current $1,764 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) 5110 Market Street, Scaffold - Employees installing mesh for stucco were exposed to a collapse hazard as the tubular welded frame scaffold did not bear on base plates or a firm foundation. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $1764
- · Z (S) $2520
1926.451 C02 I
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) 5110 Market Street, Scaffold - Employees were applying stucco mesh from a tubular welded frame scaffold that did not have level, sound and rigid footings, exposing employees to a collapse hazard. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $1,800 · Current $1,260 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) 5110 Market Street, Scaffold - A ladder or other safe means of access was not provided to employees performing stucco operations on a tubular welded frame scaffold. Employees were using the side frame as a means of access/egress, thus being exposed to fall hazards up to twenty-six (26) feet above ground level. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $1260
- · Z (S) $1800
1926.451 G01 VII
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $1,800 · Current $1,260 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 5110 Market Street, Scaffold - Employees applying stucco mesh from a tubular welded frame scaffold were exposed to a fall hazard of approximately twenty-six (26) feet without the use of a personal fall arrest system or guardrail systems. Employees were working on the 4th level outrigger section. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $1260
- · Z (S) $1800
1926.452 C02
- Issued
- May 10, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $2,520 · Current $1,762 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would automatically square and level: a) 5110 Market Street, Scaffold - The base frames of the tubular welded frame scaffold did not have any cross or diagonal braces to secure vertical members together laterally. This condition exposed employees to a collapse hazard while performing stucco operations. Observed on or about April 16, 2013.
Recent events (2)
- · I (S) $1762
- · Z (S) $2520
More inspections in this industry (NAICS 238140)