Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENDRICKSON AUXILIARY AXLE SYSTEMS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HENDRICKSON AUXILIARY AXLE SYSTEMS in 277 N. HIGH STREET, HEBRON, OH 43025 (NAICS 336399). OSHA activity number 339009896.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hendrickson Auxiliary Axle Systems — free Get an email when a new federal OSHA severe-injury report for Hendrickson Auxiliary Axle Systems is published. One employer, no account, unsubscribe in one click.
Site address
277 N. HIGH STREET
City
HEBRON
State
OH
ZIP
43025
Mailing
277 N. HIGH STREET, HEBRON, OH 43025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
100
Ownership type
A

7 citations on file for this inspection.

1910.106 F03 VI

Serious Gravity 1 1 instance 10 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.106(f)(3)(vi): Container filling facilities. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.    a. In the paint department, flammable liquids (Patriot Black A.D. Enamel Paint) were not bonded and grounded to the dispensing containers.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.212 A01

Serious Gravity 1 1 instance 50 exposed
Issued
May 10, 2013
Abate by
May 29, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a. In the maintenance area, rotating parts on the JET drill press were not guarded.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.212 A03 II

Serious Gravity 5 2 instances 32 exposed
Issued
May 10, 2013
Abate by
Aug 15, 2013
Penalty
Initial $4,250 · Current $2,125 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    a. In the HLM Bushing area, the point of operation on the Hendrickson Turner Bushing Press (Equipment # BP003) was not guarded.     b. In department 310, the point of operation on the straightening press was not guarded.
Recent events (2)
  • — I (S) $2125
  • — Z (S) $4250

1910.303 F01

Serious Gravity 1 1 instance 50 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.303(f)(1): Motors and appliances. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.     a. In the work center 110 area, the electrical disconnect for the Delta Weld 451 was not marked to indicate it's purpose.     b. In the work center 110 area, the electrical disconnect for the Miller Access 450 welder was not marked to indicate it's purpose.     c. In the work center 110 area, the electrical disconnect for the Miller XMT Welder was not marked to indicate it's purpose.     d. In the work center 110 area, the electrical disconnect for the Downdraft 7745 dust collector was not marked to indicate it's purpose.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.305 G01 IV

Serious Gravity 1 1 instance 5 exposed
Issued
May 10, 2013
Abate by
May 10, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:    29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure.     a. In the pre-plumb area, flexible cords were used in place of fixed wiring for a 110V outlet.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.157 E02

Other-than-serious 1 instance 30 exposed
Issued
May 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.  a. In the HLM Bushing area, a portable fire extinguisher was not inspected at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 E01

Other-than-serious 1 instance 5 exposed
Issued
May 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment:  29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary.  a. In the R & D area, voltage markings were not present on the electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Hendrickson Auxiliary Axle Systems's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339009896.