Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAN FLADELAND WELL SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAN FLADELAND WELL SERVICE in APPROXIMATELY 1 MILE SOUTH OF INTERSECTION HIGHWAY 23 & 82ND AVENUE NW, NEW TOWN, ND 58763 (NAICS 213112). OSHA activity number 339010340.

Watch DAN Fladeland Well Service — free Get an email when a new federal OSHA severe-injury report for DAN Fladeland Well Service is published. One employer, no account, unsubscribe in one click.
Site address
APPROXIMATELY 1 MILE SOUTH OF INTERSECTION HIGHWAY 23 & 82ND AVENUE NW
City
NEW TOWN
State
ND
ZIP
58763
Mailing
P.O. BOX 99, VELVA, ND 58790
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
15
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards:   (a)  On or about April 17, 2013, approximately three employees were exposed to fall hazards where the employer failed to properly install the emergency egress or Geronimo line.  The ground anchor point or dead man was measured at approximately 70 feet and the upper anchor point was at approximately 50 feet from the ground, creating an angle in excess of 45 degrees.  Located at Bandit 1-29, approximately one mile south of the intersection of Highway 23 and 82nd Avenue NW, near New Town, ND.   Note: Among other means, a feasible and acceptable means of abatement would be for the employer to correctly install a safety slide or Geronimo line in accordance with the best established industry practices.  The manufacturer's guidance, which identifies the requirements for the Geronimo line being anchored to the ground at a distance of twice the working platform's height, and references established by the (API) American Petroleum Institute Recommended Practice 54, Third Edition "Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations", section 6.10, "AUXILIARY ESCAPE", subsection 6.10.1, "It is recommended that the ground anchor point of the escape line should be located a minimum lateral distance from the derrick or mast equal to two times the height of the work platform.  If the rig configuration or location configuration will not permit use of the escape system, an alternate means of fast emergency exit from the derrickman's working platform to a safe place should be provided."
Recent events (1)
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339010340.