Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VAUGHAN RESTORATION MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VAUGHAN RESTORATION MASONRY, INC. in 2126 CONNECTICUT AVE., NW, WASHINGTON, DC 20005 (NAICS 238140). OSHA activity number 339011256.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vaughan Restoration Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Vaughan Restoration Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2126 CONNECTICUT AVE., NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
3916 WHEELER AVE., ALEXANDRIA, VA 22304
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 2 exposed
Issued
May 23, 2013
Abate by
May 30, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided:   a)  Connecticut Ave. and Kalorama Rd. Exposures - Mason using hand tools and portable electric power tools to remove mortar from mortar joints were not made to use eye protection that had been provided by their employer, on or about 04/05/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.300 B01

Serious Gravity 1 1 instance 3 exposed
Issued
May 23, 2013
Abate by
May 30, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:   a) Connecticut Ave. and Kalorama Rd. Exposures - A Metabo portable electric right-angle grinder was not provided with a guard when used in conjunction with a 4 1/4 inch steel cutting wheel for removing old mortar from mortar joints, on or about 04/05/2013.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,400 · Current $1,800 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):   a)  Kalorama Rd. Exposure - Masons were exposed to a 15 foot fall form a supported scaffold platform that was not tightly planked between its uprights, on or about 04/05/2013.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2400

1926.451 F07

Serious Gravity 5 1 instance 5 exposed
Issued
May 23, 2013
Abate by
Jul 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person:   a)  Connecticut Ave. and Kalorama Rd. Exposures - The site competent person supervised the erection of a supported (tubular welded frame scaffold) scaffold which was not provided with standard guard rails, toe boards or similar means of falling object protection or fully planked work platforms, on or about 04/05/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 3 exposed
Issued
May 23, 2013
Abate by
Jun 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a)  Kalorama Rd. Exposure - Masons were exposed to a 15 foot fall from a supported scaffold platform which had not been provided with standard guard rails or other suitable means of fall protection, on or about 04/05/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H02

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2013
Abate by
Jun 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(2): Employees working below a scaffold were not protected from falling tools, materials or equipment in accordance with the provisions of paragraphs (h)(2)(i)-(v) of this section:   a)  Kalorama Rd. Exposure - A mason tender working/walking next to the platform of a supported scaffold and was exposed to a struck by hazard from two 5 gallon buckets that were half filled with mortar and unrestrained from falling, on or about 04/05/2013   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Vaughan Restoration Masonry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339011256.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.