Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: ROOF DECKS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROOF DECKS, LLC in 3885 ALTAMA AVENUE, BRUNSWICK, GA 31520 (NAICS 238160). OSHA activity number 339014987.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roof Decks, LLC for free Get an email when a new federal OSHA severe-injury report for Roof Decks, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ROOF DECKS, LLC
Site address
3885 ALTAMA AVENUE
City
BRUNSWICK
State
GA
ZIP
31520
Mailing
1514 BERNITA STREET, JACKSONVILLE, FL 32211
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.300 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jul 1, 2013
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1926.300(b)(2): Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.       a). On and times prior to 17 April 2013, there is a mixer drive shaft approximately 16 inches in length located on the auger side of the Strong Manufacturing Deckmate D2F Mixer (Serial #10-1525, Identification # 6009) that is not guarded, exposing employees to an in-running nip point hazard.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1926.1053 B07

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.1053(b)(7): Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.     a). On or around 8 March 2013, an extension ladder with the bottom base sitting on top of a piece of plywood due to the wet roof surface slipped and fell while an employee was using it to gain access from the Fine Arts roof to the Gymnasium roof to tie off ladder, exposing the employee to a fall of approximately 15 feet back onto the Fine Arts roof.
Recent events (2)
  • · I (S) $1224
  • · Z (S) $2040

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jul 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.104: Note: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.     29 CFR 1910.134(c)(2)(i): An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard").   a). On and times prior to 17 April 2013, employees wearing 3M 8210 N-95 particulate respirators in a voluntary use capacity when operating the Strong Manufacturing Deckmate D2F Mixer (Serial # 10-1525, Identification #6009), was not provided the information contained in Appendix D of the regulation referenced above.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339014987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.