Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: WIZ HOME IMPROVEMENTS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WIZ HOME IMPROVEMENTS LLC in 206 GARFIELD PLACE, BROOKLYN, NY 11215 (NAICS 236118). OSHA activity number 339015596.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WIZ Home Improvements LLC for free Get an email when a new federal OSHA severe-injury report for WIZ Home Improvements LLC is published. One employer, no account, unsubscribe in one click.
Site address
206 GARFIELD PLACE
City
BROOKLYN
State
NY
ZIP
11215
Mailing
124 77TH STREET, BROOKLYN, NY 11209
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
1
Ownership type
A

6 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2013
Abate by
Aug 28, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    a) 2nd floor:    An energized electrical panel board was not provided with a cover. Energized circuit breakers and electrical parts were partially exposed and partially covered with cardboard paper. On or about 04/15/13.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2000

1926.405 J01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2013
Abate by
Aug 28, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported.     a) 2nd and 3rd floor:     Energized electrical receptacles and light switches were not securely supported. They were left hanging by energized wires attached to the devices. On or about 04/15/13.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2000

1926.554 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Aug 26, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.554(a)(1): The safe working load of the overhead hoist, as determined by the manufacturer, was not indicated on the hoist:     a) Behind the house, south side:     Employees were operating an overhead hoist motor to hoist a single-point suspension scaffold and a section of metal ventilation duct. The safe working load of the overhead hoist, as determined by the manufacturer, was not indicated on the hoist. On or about 04/15/13.     NOTE:  IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2800

1926.554 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2013
Abate by
Aug 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.554(a)(2): Supporting structure to which overhead host was attached did not have a safe working load equal to that of the hoist.     a) Behind the house, south side:     Employees were operating an overhead hoist motor to hoist a single-point suspension scaffold and a section of metal ventilation duct. The overhead host was attached to a roof brick chimney, which was the supporting structure for the hoist. The chimney did not have a safe working load equal to that of the hoist, and was overloaded and collapsed into brick pieces in an accident. On or about 04/15/13.     NOTE:  IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.1053 A09

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2013
Abate by
Aug 28, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(a)(9): The side rails of ladders were spliced and the strength of the resulting side rail was not at least equivalent to a one-piece side rail made of the same material.     a) 3rd floor:     Employees used a portable extension ladder for access to the roof to anchor a suspension scaffold and a hoist system. The ladder was made of aluminum and was spliced with extension of both side rails and an additional rung made of wood. The strength of the resulting side rails was not at least equivalent to a one-piece side rail made of the same material. On or about 04/15/13.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2013
Abate by
Aug 28, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed; the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.     a) 3rd floor:     Employees used a portable extension ladder for access to the roof to anchor a suspension scaffold and a hoist system. The ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed. The ladder also was not secured at its top. On or about 04/15/13.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2000

View WIZ Home Improvements LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339015596.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.