Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN PAINTERS INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of AMERICAN PAINTERS INC. in 11707 GOTHIC LANE, TAMPA, FL 33626 (NAICS 238320). OSHA activity number 339016040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Painters INC. — free Get an email when a new federal OSHA severe-injury report for American Painters INC. is published. One employer, no account, unsubscribe in one click.
Site address
11707 GOTHIC LANE
City
TAMPA
State
FL
ZIP
33626
Mailing
12024 STEPPINGSTONE BLVD, TAMPA, FL 33635
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
11
Ownership type
A

5 citations on file for this inspection.

1926.1053 B15

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 18, 2013
Abate by
Sep 24, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use:  (a) Ladder used by an employee while pressure washing a house was not inspected by a competent person for visual defects on a periodic basis. The ladder was determined to have defects such as, but not limited to: damaged safety feet; damaged rung lock springs that prevented the rung locks from engaging; and paint build up on the rope pulley system which prevented the pulleys from moving freely, on or about 4/2013.
Recent events (1)
  • — Z (S) $2800

1926.1053 B16

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired:  (a) On or about April 20, 2013, a ladder with structural defects was not removed from service, but instead was used by an employee while pressure washing a house. The ladder had defects such as, but not limited to: damaged safety feet; damaged rung lock springs that prevented the rung locks from engaging; and paint build up on the rope pulley system which prevented the pulleys from moving freely.
Recent events (1)
  • — Z (S) $0

1926.1060 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 18, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1060(a)(1): 1926.1060(a)(1):  The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards.  (a) For an employee standing on a portable ladder used as a platform to power wash the exterior of a house; the employee was not trained by a competent person.
Recent events (1)
  • — Z (S) $2800

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Sep 18, 2013
Abate by
Oct 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) At the site, an employee using a respirator while spray painting had not been provided a medical evaluation to determine their ability to use the respirator.
Recent events (1)
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Sep 18, 2013
Abate by
Oct 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested  (a) At the site, an employee using a tight-fitting respirator while spray painting had not been fit tested, on or about 4/20/2013.
Recent events (1)
  • — Z (O) $0

View American Painters INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339016040.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.