OSHA Inspection: ADAIR GRAIN, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ADAIR GRAIN, INC. in 1471 JERRY MASHEK DRIVE, WEST, TX 76691 (NAICS 424910). OSHA activity number 339017188.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adair Grain, INC. for free Get an email when a new federal OSHA severe-injury report for Adair Grain, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ADAIR GRAIN, INC.
Site address
1471 JERRY MASHEK DRIVE
City
WEST
State
TX
ZIP
76691
Mailing
510 ADAIR DRIVE, WEST, TX 76691
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424910
Employees
13
Ownership type
Private (A)

26 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of chemical burns and inhalation of anhydrous ammonia.    On or about April 17, 2013 and at times prior thereto, at the south end of the fertilizer plant employees working with or in proximity to two large 12,000 gallon liquid anhydrous ammonia storage/service tanks were exposed to the hazards of contact with liquid ammonia and inhalation of ammonia vapor from leaking or failed ammonia systems.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.111 B09 III

Serious Gravity 5 2 instances 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.111(b)(9)(iii): Safety relief devices used in systems covered by paragraphs (c), (f), (g), and (h) of this section were not constructed to discharge at not less than the rates required in paragraph (b)(9)(i) of this section before the pressure is in excess of 120 percent (not including the 10 percent tolerance referred to in paragraph (b)(9)(ii) of this section) of the maximum permitted start-to-discharge pressure setting of the device.    On or about April 17, 2013 and at times prior thereto, the employer did not ensure the safety relief devices for the main storage/service tanks were rated at not less than the tanks minimum rate of discharge in cubic feet per minute.       a)    On the north main stationary storage/service tank  b)    On the south main stationary storage/service tank
Recent events (3)
  • · F (S) $0
  • · C (S) $3500
  • · Z (S) $3500

1910.109 I02 III B

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
29 CFR 1910.109(i)(2)(iii)(b): Storage buildings did not have adequate ventilation or were not constructed to be self-ventilating in the event of fire.       On or about April 17, 2013, and times prior thereto, the employer did not provide suitable ventilation or self-ventilation in the fertilizer plant where ammonium nitrate was stored and handled in case of a fire.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I02 III C

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
29 CFR 1910.109(i)(2)(iii)(c): Walls on exposed sides of storage buildings within 50 feet of combustible buildings, forests, piles of combustible materials and similar exposure hazards were not of fire-resistive construction:    On or about April 17, 2013 and at times prior thereto, the employer did not ensure that the east wall of the fertilizer building and seed room were fire resistant rated and was not located within 50 feet of the office/maintenance shop building.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I02 III D

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
29 CFR 1910.109(i)(2)(iii)(d): Flooring in storage and handling areas was not without open drains, traps, tunnels, pits, or pockets into which molten ammonium nitrate could flow and be confined in the event of fire:     On or about April 17, 2013 and at times prior thereto, the employer did not ensure that the flooring on the west side of the large ammonium nitrate bin did not contain a pit for the bucket conveyor leg into which molten ammonium nitrate could flow.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I04 I B

Other-than-serious 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $2,000 Reduced
29 CFR 1910.109(i)(4)(i)(b): Bulk storage structures exceeded a height of 40 feet where storage facilities were not constructed of noncombustible materials or adequate facilities for fighting a roof fire were not available:        On or about April 17, 2013, and times prior thereto, the employer did not ensure that the ammonium nitrate storage structure that exceeded 40 feet was made of noncombustible material or that facilities for fighting a roof fire were made available.
Recent events (3)
  • · F (O) $2000
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I04 II B

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
29 CFR 1910.109(i)(4)(ii)(b): Wooden bins were not protected against impregnation by ammonium nitrate:    On or about April 17, 2013, and times prior thereto, the employer did not ensure the wooden bins used for storing ammonia nitrate were treated to prevent impregnation.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I05 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.109(i)(5)(i)(a): Ammonium nitrate was not in a separate building or was not separated by approved type firewalls of not less than 1 hour fire-resistance rating from storage of flammable and combustible materials or other contaminating materials:    On or about April 17, 2013 and times prior thereto, the employer did not ensure that flammable and combustible materials such as but not limited to seed, paper seed bags, wood pallets, and baling twine, were not stored in the same building with ammonium nitrate.  The bin wall separating the ammonium nitrate from the seed room was not fire rated.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I04 III B

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.109(i)(4)(iii)(b): Height or depth of piles was not limited by the pressure-setting tendency of the product:  On or about April 17, 2013 and at times prior thereto, the employer did not ensure the height or depth of ammonium nitrate piles in bins was determined by the pressure setting tendencies of the ammonium nitrate.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

1910.109 I07 II B

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $7,000 · Current $6,700 Reduced
29 CFR 1910.109(i)(7)(ii)(b): Water supplies and fire hydrants were not available in accordance with recognized good practice:     On or about April 17, 2013, and times prior thereto, the employer did not ensure that suitable water supplies and fire hydrants were available in accordance with recognized good practice at the fertilizer plant where ammonium nitrate was stored in the event of a fire.
Recent events (3)
  • · F (S) $6700
  • · C (S) $7000
  • · Z (S) $7000

1910.111 B03 I

Other-than-serious 1 instance 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.111(b)(3)(i): System nameplates, when required, were not permanently attached to the system so as to be readily accessible for inspection and did not include markings as prescribed in subdivision (ii) of this subparagraph:     On or about April 17, 2013, and at times prior thereto, the employer did not ensure that the south main anhydrous ammonia storage/service tank had a system nameplate.
Recent events (3)
  • · F (O) $2000
  • · C (S) $3500
  • · Z (S) $3500

1910.111 B03 II A

Serious Gravity 1 2 instances 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $2,100 · Current $6,700
29 CFR 1910.111(b)(3)(ii)(a): Each container or system covered in paragraphs (c), (f), (g), and (h) of this section were not marked with a notation "Anhydrous Ammonia".    On or about April 17, 2013 and at times prior thereto, the employer did not ensure that the main anhydrous ammonia storage/service tanks were labeled, with the visible words "Anhydrous Ammonia".      a)    On the north stationary main storage/service tank  b)    On the south stationary main storage/service tank
Recent events (3)
  • · F (S) $6700
  • · C (S) $2100
  • · Z (S) $2100

1910.1200 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On or about April 17, 2013, and at time prior to, the employer did not develop or implement a hazard communication program for employees working with chemicals, such as but not limited to, anhydrous ammonia and ammonium nitrate.  The employer did not inform the employees of the potential hazards of these chemicals which include, chemical burns, respiratory illness, fire and explosion.
Recent events (3)
  • · F (S) $0
  • · C (S) $3500
  • · Z (S) $3500

1910.111 B08 II

Serious Gravity 10 6 instances 3 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $4,900 · Current $6,700
29 CFR 1910.111(b)(8)(ii): Hose assemblies, when made up, were not capable of withstanding a test pressure of 500 p.s.i.g.    On or about April 17, 2013 and at times prior thereto, the employer did not ensure that when new Parker 7261 anhydrous ammonia system hoses were installed or replaced that they were tested to withstand a test pressure of at least 500 p.s.i.g.
Recent events (3)
  • · F (S) $6700
  • · C (S) $4900
  • · Z (S) $4900

1910.111 C02 I

Serious Gravity 10 4 instances 3 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $4,900 · Current $6,700
29 CFR 1910.111(c)(2)(i): Each filling connection was not provided with combination back-pressure check valve and excess-flow valve; one double or two single back-pressure check valves; or a positive shutoff valve in conjunction with either an internal back-pressure check valve or an internal excess flow valve.    On or about April 17, 2013 and at times prior thereto, the employer did not ensure that anhydrous ammonia compressors and liquid and vapor filling/service lines had back pressure check valves and/or excess flow valves installed.       a)    At the north tank filling/servicing pump house  b)    At the north tank rail side filling/servicing lines  c)    At the south tank filling/servicing bonnet  d)    At the south filling/servicing island
Recent events (3)
  • · F (S) $6700
  • · C (S) $4900
  • · Z (S) $4900

1910.111 C07

Other-than-serious 1 instance 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.111(c)(7): Precautions were not taken against damage to ammonia systems from vehicles.    On or about April 17, 2013 and at times prior thereto, on the rail side of the main anhydrous ammonia storage/service tanks, the employer did not ensure that the main piping and valves were protected from being struck-by vehicles and other equipment loading, unloading and working in the area.
Recent events (3)
  • · F (O) $2000
  • · C (S) $3500
  • · Z (S) $3500

1910.120 Q02

Serious Gravity 5 1 instance 13 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $6,700
29 CFR 1910.120(q)(2): The employer did not develop an emergency response plan for emergencies which addressed the following minimum requirements of this standard: 1910.120(q)(2)(i) through 1910.120(q)(2)(xii):    On or about April 17, 2013 and at times prior thereto, the employer received, stored and handled hazardous chemicals such as anhydrous ammonia and did not implement an emergency response plan or procedures to handle anticipated emergencies.
Recent events (3)
  • · F (S) $6700
  • · C (S) $3500
  • · Z (S) $3500

1910.134 C01

Other-than-serious 1 instance 6 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    On or about April 17, 2013, and times prior thereto, the employer did not implement a written respiratory protection program for employees required to wear half-face and full-face respirators during exposure to inhalation hazards, while servicing anhydrous ammonia storage/service tanks, nurse tanks and performing other tasks.
Recent events (3)
  • · F (O) $2000
  • · C (S) $3500
  • · Z (S) $3500

1910.134 E01

Other-than-serious 1 instance 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:    On or about April 17, 2013, and times prior thereto, the employer did not provide a medical evaluation for employees required to wear half-face and full-face respirators during an unexpected leak/exposure when servicing Anhydrous Ammonia service/storage tanks, nurse tanks and maintenance on the anhydrous ammonia systems.
Recent events (3)
  • · F (O) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 F02

Other-than-serious 1 instance 6 exposed
Issued
Oct 9, 2013
Abate by
Nov 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting face-piece respirators were not fit tested prior to initial use of the respirator:    On or about April 17, 2013, and times prior thereto, the employer did not provide fit tests for employees required to wear half-face and full-face respirators during an unexpected leak/release when servicing Anhydrous Ammonia service/storage tanks, nurse tanks and maintenance on Anhydrous Ammonia systems.
Recent events (3)
  • · F (O) $0
  • · C (S) $0
  • · Z (S) $0

1910.146 C01

Other-than-serious 1 instance 4 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    On or about April 17, 2013, and at times prior thereto, the employer did not evaluate or determine if any spaces were permit required spaces prior to allowing employees to enter for cleaning.      a) Grain silos  b) 32-0-0 liquid fertilizer tanks
Recent events (3)
  • · F (O) $2000
  • · C (S) $3500
  • · Z (S) $3500

1910.147 C01

Other-than-serious 1 instance 6 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $4,900 · Current $2,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative:     On or about April 17, 2013 and at times prior thereto, the employer did not develop or implement an energy control program or procedures for equipment such as but not limited to, grain augers, sweepers and conveyers, rail car wenches, and dry fertilizer bucket and belt conveyors where the employees performed routine and periodic servicing and maintenance.
Recent events (3)
  • · F (O) $2000
  • · C (S) $4900
  • · Z (S) $4900

1910.157 D01

Other-than-serious 1 instance 3 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $2,100 · Current $2,000 Reduced
29 CFR 1910.157(d)(1): Portable fire extinguishers were not selected based on the classes of anticipated workplace fires and on the size and degree of hazard which would affect their use:    On or about April 17, 2013, and at times prior thereto, the employer did not select and provide the type of fire extinguishers for materials such as but not limited to oxidizers stored in the fertilizer plant.
Recent events (3)
  • · F (O) $2000
  • · C (S) $2100
  • · Z (S) $2100

1910.178 L06

Other-than-serious 1 instance 6 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    On or about April 17, 2013 and at times prior thereto, the employer did not certify that each operator was provided training consisting of a combination of formal instruction, practical training and an evaluation of their performance prior to operating fork lift trucks.
Recent events (3)
  • · F (O) $2000
  • · C (S) $3500
  • · Z (S) $3500

1910.178 Q07

Other-than-serious 1 instance 6 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    On or about April 17, 2013 and at times prior thereto, the employer did not ensure that forklift trucks were inspected prior to use by employees.
Recent events (3)
  • · F (O) $0
  • · C (S) $3500
  • · Z (S) $3500

1910.303 B01

Other-than-serious 10 instances 5 exposed
Issued
Oct 9, 2013
Abate by
Nov 7, 2013
Penalty
Initial $4,900 · Current $2,000 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):    On or about April 17, 2013 and at times prior thereto, the employer installed spliced two-wire unprotected light bulb sockets hanging freely above each dry fertilizer bin.
Recent events (3)
  • · F (O) $2000
  • · C (S) $4900
  • · Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339017188.