OSHA Inspection: BAILEY PALLET, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BAILEY PALLET, LLC in 4941 APPLE STREET, BOISE, ID 83716 (NAICS 321920). OSHA activity number 339017428.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bailey Pallet, LLC for free Get an email when a new federal OSHA severe-injury report for Bailey Pallet, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BAILEY PALLET, LLC
Site address
4941 APPLE STREET
City
BOISE
State
ID
ZIP
83716
Mailing
OREGON PALLET REPAIR, INC. PO BOX 12447, SALEM, OR 97309
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
10
Ownership type
Private (A)

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 5, 2013
Abate by
Jul 17, 2013
Penalty
Initial $1,360 · Current $952 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of being thrown from, pinned under, or crushed by a powered industrial truck (forklift) when operating the equipment without a seat belt:  a) Yard area: On April 19, 2013 and at times prior thereto employee(s) operated the powered industrial truck(s) without wearing the seatbelt(s) that were available.   Note) Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1910.133 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 5, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee, who wore prescription lenses while engaged in operations that involved eye hazards, used protection that incorporated the prescription in its design, or wore eye protection over the prescription glasses or protective lenses with side shields:  a) Pallet build-up area: On April 19, 2013 and at times prior thereto an employee wore prescription eyewear only while performing pallet build-up, using a pneumatic nail gun.    Note) Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $1190
  • · Z (S) $1700

1910.303 G02 I

Serious Gravity 1 1 instance 8 exposed
Issued
Jul 5, 2013
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:  a) Dismantler machine: On April 19, 2013 and at times prior thereto the side power panel door on the Smetco dismantler machine was not effectively closed.  This allowed potential employee exposure to live electrical parts and allowed dust and other debris to accumulate inside.  Note) Abatement certification is NOT required for this item.
Recent events (2)
  • · I (S) $714
  • · Z (S) $1020

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 5, 2013
Abate by
Jul 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Outside of main work shop: On April 19, 2013 and at times prior thereto a flexible cord that was wired into a power panel inside the main shop was used for permanent power to the Smetco notcher that was located outside of the main shop.    Note) Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV C

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 5, 2013
Abate by
Jul 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables where run through doorways, windows, or similar openings:  a) Notcher machine: On April 19, 2013 and at times prior thereto the power cord for the Smetco notcher machine was run through a doorway, to the outside of the building where the machine was located.    Note) Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 5, 2013
Abate by
Jul 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:  a) Notcher machine: On April 19, 2013 and at times prior thereto the power cable strain relief device was pulled out and away from the power panel box.    Note) Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339017428.