Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: C & G REFRIGERATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C & G REFRIGERATION, INC. in 110 WESTMINSTER AVENUE, HANOVER, PA 17331 (NAICS 238220). OSHA activity number 339017600.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & G Refrigeration, INC. for free Get an email when a new federal OSHA severe-injury report for C & G Refrigeration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
110 WESTMINSTER AVENUE
City
HANOVER
State
PA
ZIP
17331
Mailing
2640 BALTIMORE PIKE, HANOVER, PA 17331
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1926.651 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees:    (a) 110 Westminster Avenue, Hanover, Pennsylvania - The employer opened an excavation in the front yard of the residence in order to replace the sanitary sewer line from the house to the township sanitary sewer line.  The employer did not protect, support, or remove the underground natural gas line to prevent damage to the line.  On April 19, 2013, the trench collapsed onto the natural gas line, tearing the gas line loose and creating the hazard of a fire and explosion from a natural gas release.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (3)
  • · C (S) $2000
  • · F (S) $1000
  • · Z (S) $2000

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    (a) 110 Westminster Avenue, Hanover, Pennsylvania - An employee worked in the trench, dug in the front yard of the residence, to install and connect a new sanitary sewer line to the residence.  The employer did not keep the pile of soil excavated from the trench and placed along the east wall of the trench at least two feet from the edge of the trench nor use retaining devices to keep the excavated material from falling into the trench and striking the employee working in the trench, on or about April 19, 2013.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (3)
  • · C (S) $2000
  • · F (S) $1000
  • · Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.652(a)(1): 29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):     (a) 110 Westminster Avenue, Hanover, Pennsylvania - On or about April 19, 2013, an employee worked in a trench, dug in Type B soil at best, to connect new sanitary sewer piping.  The trench where the employee worked had a depth of 7 feet 4 inches, had vertical side walls, and had no cave-in protection.  On April 19, 2013, the western wall of the trench collapsed.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (3)
  • · C (S) $2800
  • · F (S) $1000
  • · Z (S) $2800

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:   (a) 110 Westminster Avenue, Hanover, Pennsylvania - On April 19, 2013, the site did not have a competent person to inspect the trench in that the person in charge did not have an understanding of soil classifications, did not classify the soil in the trench in order to determine the appropriate cave-in protection to install, and did not install cave-in protection in the trench.  The trench, dug in Type B soil at best, had a depth of 7 feet 4 inches where an employee worked in the trench to connect new sanitary sewer piping.   Additionally, this 25-foot long trench did not have the excavated soil pile at least 2 feet back from the edge along the eastern wall and did not have a natural gas line located within the trench protected or supported.  On April 19, 2013, the western wall of the trench collapsed.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (3)
  • · C (S) $0
  • · F (S) $0
  • · Z (S) $0

View C & G Refrigeration, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339017600.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.